Miele T 8002, T 8005, T 8003 manual Length

Page 40

Installation

Example: Calculating the effective duct length and required internal duct diameter

Rigid pipe

 

Duct length

Duct length

 

 

ft

m

 

 

 

 

A

Wall duct with

12’ 5"

3.8 m

 

louvered wall vent

 

 

 

 

 

 

B

90° bend

2’ 7"

0.8 m

 

 

 

 

C

20" (0.5 m) rigid pipe

1’ 7"

0.5 m

 

 

 

 

D

90° bend

2’ 7"

0.8 m

 

 

 

 

E

left vent opening

3’ 3"

1.0 m

 

 

 

 

Total duct

 

22’ 5"

6.9 m

length

 

 

 

 

 

 

 

The total duct length is less than 33 feet (10 m), so a duct diameter of 4" (100 mm) with adapter is sufficient.

36

Image 40
Contents Vented Dryer 8002 T 8003 T Contents Important Safety Instructions This dryer is intended for residential use only Grounding InstructionsControl panel Before loading the dryer Program recommendationsTurn on the dryer and load the laundry Using the dryerSelect a program Program When to use Extra DrySelect a drying option if needed TurboFull load GentleSelect the dryness level To adjust the buzzer volumeSelect the buzzer if desired Start the program At the end of a programCanceling or changing a program Adding or removing laundry during a programChild lock Child lockTo activate the child lock To deactivate the child lockCleaning the lint filters Dryer careCleaning the grille filters Cleaning the exterior and the control panel Cleaning the drumChanging the light bulb Frequently asked questions What if the dryer will not run? Possible fault SolutionWhat if the Filter/Vent fault indicator is lit? Possible fault SolutionWhat if the laundry is not dry enough? Possible fault After sales service PC UpdateRepairs MieleCareQuick Guide Remove this guide for easy referenceQuick Guide Turn on the dryer and load the laundrySelect a program Select a drying option if desiredQuick Guide At the end of a programFor uniform loads, e.g. sheets Underwear, socks Installation Instructions Important Safety Instructions Save These Instructions Height of vent adapter in a stacked installation Washer / Dryer StackElectrical connection Installation Installation Installation siteTransporting the dryer to the installation site Rear viewInstallation beneath a counter Reinstallation of the machine lidDetermining the position of the exhaust connection Leveling the dryerChanging the position of the exhaust connection Installation tips Room ventilationWindow connection Exhaust connectionWall connection with rigid pipe Direct wall connection Dryer top viewHow to calculate the effective duct length Tips about the duct work Additional duct lengths 4 rigid pipe only Length Disposal of the packing materials Caring for the environmentDisposal of an appliance Page