Troubles
Interferences from the ambient (for example electrical wiring) could induce signalization of different faults. In such cases:
-switch the appliance off, and wait for a few seconds;
-plug in the appliance and repeat the drying program.
If the fault repeats, call authorized service shop.
Warranty shall not apply in case of failures due to interferences from the environment (lightning stroke, power supply circuit faults, natural disasters).
TroubleCheck
Appliance does not • If there is current in the socket and if the fuse is
work:functioning.
• If the plug is correctly inserted into the socket.
There is current in the socket, but the drum is not rolling:
•If the door is closed tightly (press it towards the appliance).
•If the program runs according to instructions.
•If the container is full (only with condensation dryer),
•If appropriate drying time is selected.
Laundry is not dry: | • | If the filter is clean. | ||
| • | If the condensation device is clean (only with | ||
|
| condensation dryer). | ||
| • | If the room is adequately ventilated. | ||
| • | If the amount of laundry to be dried is not too big. | ||
| • | If the evacuation tube is too long (only with | ||
|
| evacuation dryer - max 2 m). | ||
| • If the laundry loaded in the drum has not been | |||
|
| spun enough or if appropriate drying time has been | ||
|
| set. | ||
| • | If the room is too hot (over 25°C, applies for | ||
|
| condensation dryer). |
| |
The condensation is | • If the room temperature is too high. | |||
inadequate: | • | If the condensation device is clean. | ||
|
|