22
When checking voltage between connectors
( , ) on spinning, is the voltage 220 - 240V~ as the figure?
NO
YES
DRAIN MALFUNCTIONINGNO YES
Is the drain hose twistedNOor frozen?YES
Is the impeller of the drainNOpump clogged? YES
Is the connector disconnected,NOdisassembled? YES
Is the coil of the drain pump cut-off? NO (resistance of coil is 90~160 )
Checking voltage between two pins as press the POWER button is the voltage 220 - 240V~?
When pressing Opt. 2 and Time Delay at the same time after draining, is the water level frequency 252 or more? When pressingYESOpt. 2, Time Delay buttons at the same time while wash, is the water level frequency between
230 - 243 ?
HEATING WITHOUT WATER
MAINPWBASSEMBLY |
MAINPWBASSEMBLY12
Replace the
S.PRESSURE SWITCH ASSEMBLY
Replace the MAIN PWB ASSEMBLY
Repair the DRAIN HOSE ASSEMBLY.
Remove foreign material.
Reconnect or repair the connector
Repair the DRAIN PUMP ASSEMBLY.
Repair the MAIN PWB ASSEMBLY.