30-Inch Manual-Clean Electric Coil Slide-Ins
22-46262
page 2 of 2
For existing 29" cutout width |
|
|
|
|
|
opening, you must call the Sears Service | 30" Min. | ||||
Center for optional thinner side panels. |
|
|
|
|
|
Also you must prepare the countertop |
|
| 13" |
|
|
|
|
| |||
edge as shown in “Counterdepth |
|
|
|
|
|
|
|
|
|
| |
Preparation”. |
|
|
|
|
|
Shave Raised | 30" Min.* |
| |||
Edge To Clear |
|
|
| 18" Min. |
311/2" Wide Cooktop.
1 1/2" Max. |
| 30"† |
|
| ±1/16" |
| 36 5/8" Max. | Approx. 1 7/8" |
| 35 5/8" Min. | |
| 21 3/4" | 24" Min. |
| min.** | |
Locate Cabinet | 22 1/8" |
|
max. |
|
Doors 1" Min. From
Cutout Opening
Grounded Junction Box or Wall Outlet Should Be Located 8" to 17" (20.3 - 43.2 cm) From Right of Cabinet and 2" to 4" From Floor
Do not pinch the power supply cord between the range and the wall. Do not seal the range to the side cabinets.
*Note: 24" min. clearance between the cooktop and the bottom of the cabinet when the bottom of the wood or metal cabinet is protected by not less than 1/4" flame retardant millboard covered with not less than No. 28 MSG sheet metal, 0.015" stainless steel, 0.024" aluminum, or 0.020" copper. 30" min. clearance when the cabinet is unprotected.
**Note: Minimum cutout depth is increased to 24" with optional backguard.
†Note: To avoid cooktop glass breakage for cutout width of more than 30 1/16", make sure appliance is centered in the counter opening while pushing
into it. Raise leveling legs at maximum position, insert the appliance in the counter and then level. Make sure the unit is supported by the leveling legs and not by the smoothtop glass itself.
††For cutouts below 22 7/8”, appliance will slightly show out of the cabinet. +Allow at least 19 1/4" clearance for door depth when it is open.
COUNTERTOP PREPARATION
The cooktop sides of the range fit over the cutout edge of your countertop.
Countertop must be level.
If you have a square finish (flat) countertop, no countertop preparation is required. Cooktop sides lay directly on edge of countertop.
Formed
Tile countertops may need trim cut back 3/4" from each front corner and/or rounded edge flattened.
If the existing cutout width is greater than 30 1/16", reduce the 3/4" dimension.
| Min. | 3/4" |
| cutout |
|
| width | Formed or tiled |
| 31 1/2" | |
| countertop | |
|
| trimmed 3/4" back |
| 3/4" | at front corners of |
| countertop opening. | |
|
| 28 5/16" |
| 22 7/8" min.†† | 21 3/4" |
| 23 1/4" max. | 31 1/2" |
| 1 1/8" |
|
| 21 3/4" min. | 35 5/8" - |
CABINET | 36 3/8" | |
FRONT | 22 1/8" max. | Door Open+ |
| ||
|
|
Side Panel
30"
RANGE CORD REQUIRED | ||||
Order | Wire | Length |
| |
|
| |||
| 3 | 4 ft. |
| |
| 3 | 6 ft. |
| |
| 4 | 4 ft. |
| |
| 4 | 6 ft. |
|
*Complies with 1/1/96 NEC code revision for new construction and remodeling
07806
Because of our continuous program of product improvement, Sears reserves the right to change materials and specifications without notice. Consult installation instructions packed with the product for final dimensional data. For complete warranty information, contact your local Sears Contract Sales Account Manager.
All ranges are equipped with an
Effective 05/31/06 Rev. 1