MOBILE HOME INSTALLATION
The installation of the Dryer in mobile homes must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR, Part
When installing a Dryer in a mobile home, provisions for anchoring the Dryer to the floor must be made. Locate an area that has adequate fresh air.
A minimum of 72 in² (465 cm²) of unobstructed space is required.
Call
The exhaust duct may not terminate underneath the mobile home. See Exhausting section for more information.
EXHAUSTING
Exhausting the Dryer to the outside will prevent large amounts of lint and moisture from being blown into the room.
In the United States:
•All dryers must be exhausted to the outside.
•The required exhaust duct is 4 inch (102 mm) in diameter.
•Only those
•The duct shall not be assembled with screws or other fastening means that extend into the duct and catch lint.
In Canada:
•Only those
•All dryers must be exhausted to the outside.
•The exhaust duct should be 4 inch (102 mm) in diameter.
Outside the U.S. and Canada:
•Refer to the local codes.
The dryer must be exhausted to the outside to reduce the risk of fire when installed in an WARNING alcove or closet.
NEVER USE A PLASTIC OR NON-METAL FLEXIBLE DUCT.
If your existing ductwork is plastic,
Use only a metal exhaust duct that is
installing your dryer _11