ELECTRICAL CONNECTIONS
FOR A 3-WIRE SYSTEM
NON-CANADIAN ELECTRIC Laundry Center
ELECTRICAL CONNECTIONS
FOR A 4-WIRE SYSTEM
NON-CANADIAN ELECTRIC Laundry Center
1. Remove the screw securing the terminal block access cover to the rear panel and remove cover.
2. Install a U.L. approved strain relief connector in the entry hole on the back panel.
3.Insert a NEMA
U.L. approved power cord through the strain relief.
4.Attach the power cord neutral (central wire) conductor to the silver colored center terminal on the terminal block. Tighten the screw securely.
GREEN GROUND SCREW | SILVER TERMINAL |
|
1. Remove the screw securing the terminal block access cover to the rear panel and remove cover.
2. Install a U.L. approved strain relief connector in the entry hole on the back panel.
3.Remove the neutral ground wire from the green ground screw located above the termial block.
NEUTRAL GROUND WIRE
NEUTRAL GROUND WIRE
5.Attach the remaining two power cord outer conductors to the outer brass colored terminals on the terminal block. Tighten both screws securely.
6.Tighten the screws securing the cord restraint against the power cord.
7.Reinstall the terminal access cover.
4.Insert a NEMA
5.Attach the green power cord ground wire to the cabinet with the green ground screw.
6.Attach the white (neutral) wire from the power cord and the neutral ground wire from the appliance harness to the silver colored center terminal on the terminal block. Tighten the screw securely.
7.Attach the red and black wires from the power cord to the outer
8.Tighten the screws securing the cord restraint firmly against the power cord.
9.Reinstall the terminal block access cover.
9