Adjusting the level of conductivity
Water contains, a variable quantity of limestone and mineral salts of which quantities vary according to geographical locations thus varying its conductivity values.
Relevant variations of the conductivity of the water compared to those prefixed by the factory could slightly influence the residual humidity of the laundry at the end of the cycle.
Your dryer allows you to regulate the sensitivity of the drying sensor based on conductivity values of the water by using the following procedure.
To access adjustment mode:
Turn the programme selector dial to switch on the appliance. In selection mode, press simultaneously the buttons 1 and 3.
Press the buttons down until the pilot lights above each ones begin to flash and one of the pilot lights indicating the drying phase lights , cooling , or end cycle remains lit.
1 | 2 | 3 | 4 |
Adjusting the level of conductivity:
Press the START/PAUSE button sequentially: the level of conductivity is indicated by the phase pilot lights, which light in various combinations as follows:
LED lit | Conductivity | Approximate value | |
µS/cm | |||
|
| ||
| Low | < 300 | |
| Medium | 300 - 600 | |
| High | > 600 |
Normally, the appliance is
Memorizing the new setting:
Simultaneously press the buttons 1 and 3.
Press the buttons down until the pilot lights above each ones stop flashing and the buzzer sounds.
14