5.A 1/8 inch (0.32 cm) N.P.T. plugged tapping, accessible for test gauge connection, MUST be installed immediately upstream of the gas supply connection to the dryer.

6.The dryer MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures in excess of 1/2 psig (3.45 kPa).

7.The dryer MUST be isolated from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures equal to or less than

1/2 psig (3.45 kPa).

LOCATION OF YOUR DRYER

DO NOT INSTALL YOUR DRYER:

1.In an area exposed to dripping water or outside weather conditions.

2.In an area where it will come in contact with curtains, drapes, or anything that will obstruct the flow of combustion and ventilation air.

3.On carpet. Floor MUST be solid with a maximum slope of 1 inch (2.54 cm).

INSTALLATION IN RECESS OR CLOSET

1.A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors.

2.No other fuel burning appliance shall be installed in the same closet as the Gas dryer.

3.Your dryer needs the space around it for proper ventilation.

DO NOT install your dryer in a closet with a solid door.

4.A minimum of 120 square inches (774.2 square cm) of opening, equally divided at the top and bottom of the door, is required. Air openings are required to be unobstructed when a door is installed. A louvered door with equivalent air openings for the full length of the door is acceptable.

MINIMUM INSTALLATION CLEARANCES - Inches (cm)

 

SIDES

REAR

TOP FRONT

Alcove

0 (0 cm)

0 (0 cm)

 

Closet

0 (0 cm)

0 (0 cm)

1 (2.54 cm)

Closet door ventilation required: 2 louvered openings each 60 square inches (387 square centimeters) — 3 inches (7.6 cm) from bottom and top of door.

This dryer MUST be exhausted outdoors.

5.The following illustrations show minimum clearance dimensions for proper operation in a recess or closet installation.

0" (0 cm)

60 sq. inches

 

(387.1 sq. cm)

0" (0 cm)

 

1" (2.54 cm)

0" (0 cm)

60 sq. inches

 

(387.1 sq. cm)

 

CLOSET DOOR

 

5

Image 5
Contents Installation Instructions PRE-INSTALLATION Requirements Safety InstructionsExhaust System Requirements Electrical RequirementsElectric Dryer Nema 10-30R Nema 14-30R GAS DryerExhaust Direction Exhaust Duct Locating DimensionsGAS Supply Requirements Installation in Recess or Closet Do not Install Your DryerLocation of Your Dryer Sides Rear TOP FrontDryer Installation Dimensions Solid Door Reversing Instructions Mobile Home InstallationReversing Door Swing Window Door Reversal Instructions Page Grounding Requirements Electrical InstallationElectrical Connections for 4-WIRE System Electrical Connections For 3-WIRE SystemGAS Connection Replacement PartsGeneral Installation − QUE Faire S’IL Y a UNE Odeur DE GAZ Avant L’INSTALLATIONOutils et matériel requis pour l’installation Évacuation DE L’AIR Installation ÉlectriqueSécheuses Électriques Sécheuses à GAZLongueur Maximum Emplacement DES Bouches D’ÉVACUATIONPoser LES Raccords Mâles Dans LA Bonne Direction Direction DE L’ÉVACUATION D’AIRNE PAS Installer LA Sécheuse Emplacement DE LA SécheuseInstallation Dans UNE Alcôve OU UN Placard Alimentation EN GAZDimensions D’Installation De Secheuse Porte Réversible DéballagePage Page Ne modifiez pas la prise équipée d’appareil Sécheuses Électriques non-CanadiennesSécheuses Électriques Canadiennes Toutes les sécheuses à GAZBranchement Électrique D’UNE Installation À 4 Fils Branchement Électrique D’UNE Installation À 3 FilsPièces DE Rechange Installation