Installation Instructions
CONNECTING AN ELECTRIC DRYER (cont.)
CONNECTING DRYER USING 3-WIRE
CONNECTION
Ground strap
Bracket
1.Turn off the circuit breaker(s) (30 amp) or remove the dryer’s circuit fuse at the electrical box.
2.Be sure the dryer cord is unplugged from the wall receptacle.
3.Remove the power cord cover located at the upper back.
4.Bring the power cord through the bracket .
5.Connect power cord as follows:
A.Connect the 2 hot lines to the outer screws of the terminal block (marked L1 and L2).
B.Connect the neutral (white) line to the center of the terminal block (marked N).
6.Be sure ground strap is connected to green ground screw on cabinet rear. Tighten all terminal block screws (3) completely.
7.Reinstall the cover.
WARNING – NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
16