GE PCVH485EK, PCVH480EK owner manual Minimum clearance to combustible surfaces

Page 28

Installation Instructions

STACKING THE WASHER AND DRYER (if desired)

If you are planning to stack the washer and dryer, order Stacking Kit number GE24STACK to be used for this dryer. Kit sold separately.

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANTSave these instructions for local electrical inspector’s use.

IMPORTANTObserve all governing codes and ordinances.

Note to Installer – Be sure to leave these instructions with the Consumer.

Note to Consumer – Keep these instructions for future reference.

Service must be performed by a qualified installer.

Proper installation is the responsibility of the installer.

Stacking installations may require a power cord up to 6 feet in length.

FOR YOUR SAFETY:

WARNING –

Electric Shock Hazard. Disconnect power before installing. Failure to do so could result in serious injury or death.

Potential Personal Injury. More than two people are recommended to lift the dryer into position because of its weight and size. Failure to do so could result in personal injury or death.

Avoid Tipping and Rupture of Utility Services. Dryer must be securely attached to the washer. DO NOT place the washer on top of the dryer. Failure to do so could result in personal injury/death or property damage.

MINIMUM CLEARANCE OTHER THAN ALCOVE OR CLOSET INSTALLATION

Minimum clearance to combustible surfaces

and for air opening are: 0both sides and 3front and rear. Consideration must be given to provide adequate clearance for installation and service.

REQUIREMENTS FOR ALCOVE OR CLOSET INSTALLATION

Your dryer is approved for installation in an alcove or closet, as stated on a label on the dryer back.

The dryer MUST be vented to the outdoors. See the EXHAUSTING THE DRYER section.

Minimum clearance between dryer cabinet and adjacent walls or other surfaces is:

0either side

3front and rear

Minimum vertical space from floor to overhead shelves, cabinets, ceilings, etc., is 67.7.

Closet doors must be louvered or otherwise ventilated and have at least 60 square inches of open area equally distributed. If the closet contains both a washer and a dryer, doors must contain a minimum of 120 square inches of open area equally distributed.

NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT THE REAR OF THE DRYER, MINIMUM CLEARANCE FROM THE WALL IS 5.5 INCHES.

28

Image 28 Contents
Dryers Proper Installation Your Laundry Area When not Using Your Dryer Power Quick StartTimed Dry Dry CyclesSensor Dry Level Clean Lint Filter message Dry TempExtend Tumble Delay StartDamp Alert Signal LockCare and Cleaning of the Dryer Sorting and Loading HintsFabric Care Labels Dry LabelsFor Your Safety Before YOU BeginUnpacking Your Dryer Dryer DimensionsElectrical Connection Undercounter Installation Bathroom or Bedroom InstallationMobile or Manufactured Home Installation Tools YOU will Need Materials YOU will NeedElectrical Requirements For Electric Dryers Grounding InstructionsInstallation Instructions Connecting AN Electric Dryer Connecting Dryer Using 3-WIRE ConnectionTools and Materials YOU will Need to Install Exhaust Duct Exhaust System ChecklistConnecting the Dryer to House Vent Do notUSE only Metal Duct 4″ Diameter 102 mm Recommended Configuration to Minimize Exhaust Blockage Standard Rear ExhaustSide Venting Adding a NEW DuctSide Venting Bottom VentingBottom Venting Level the Dryer Plug Dryer Dryer Startup ServicingImportant Notes Hardware UsedRemove the Door Assembly Before YOU StartReplace Door Assembly Minimum clearance to combustible surfaces Installing the Stack Bracket KIT Installation PreparationInstall Dryer and Bracket on Dryer Install Bracket to WasherFinalize the Installation GEAppliances.com Before you call for service… Timed DRY Clothes shrink We Will Replace What Is Not Covered in the United StatesWarrantor General Electric Company. Louisville, KY GE Dryer Warranty. For customers in Canada What Is Not Covered in CanadaConsumer Support