| MAXIMUM LENGTH |
| ||||
|
|
| |||||
| of 4” (10.2 cm) Dia. Rigid Metal Duct | ||||||
|
|
|
|
|
| ||
|
| VENT HOOD TYPE |
|
| |||
|
| (Preferred) |
|
|
| ||
Number |
|
|
| Louvered |
|
| |
of |
|
|
|
|
|
|
|
90° |
| 4” |
|
|
| 2½" | |
Turns |
|
|
|
| |||
| (10.2 cm) |
|
|
| (6.35 cm) | ||
0 | 60 | ft. | (18.28 | m) | 48 ft.(14.63 m) | ||
1 | 52 | ft. | (15.84 | m) | 40 ft.(12.19 m) | ||
2 | 44 | ft. | (13.41 | m) | 32 ft. | (9.75 m) | |
3 | 32 | ft. |
| (9.75 m) | 24 ft. | (7.31 m) | |
4 | 28 | ft. |
| (8.53 m) | 16 ft. | (4.87 m) | |
|
|
|
|
|
|
|
|
MAXIMUM LENGTH
of 4” (10.2 cm) Dia. Flexible Metal Duct
| VENT HOOD TYPE |
| |
| (Preferred) |
| |
Number | Louvered |
| |
of |
| ||
|
| ||
90° | 4” | 2½" | |
Turns | |||
(10.2 cm) | (6.35 cm) | ||
|
0 | 30 ft. | (9.14 m) | 18 ft. (5.49 m) |
1 | 22 ft. | (6.71 m) | 14 ft. (4.27 m) |
2 | 14 ft. | (4.27 m) | 10 ft. (3.05 m) |
3 |
| NOT RECOMMENDED |
CORRECTINCORRECT
INSTALL MALE FITTINGS IN CORRECT DIRECTION
In installations where the exhaust system is not described in the charts, the following method must be used to determine if the exhaust system is acceptable:
1.Connect an inclined or digital manometer between the dryer and the point the exhaust connects to the dryer.
2.Set the dryer timer and temperature to air fluff (cool down) and start the dryer.
3.Read the measurement on the manometer.
4.The system back pressure MUST NOT be higher than 0.75 inches of water column. If the system back pressure is less than 0.75 inches of water column, the system is acceptable. If the manometer reading is higher than 0.75 inches of water column, the system is too restrictive and the installation is unacceptable.
Although vertical orientation of the exhaust system is acceptable, certain extenuating circumstances could affect the performance of the dryer:
• Only the rigid metal duct work should be used.
•Venting vertical through a roof may expose the ex haust system to down drafts causing an increase in vent restriction.
•Running the exhaust system through an uninsulat- ed area may cause condensation and faster accumu lation of lint.
•Compression or crimping of the exhaust system will cause an increase in vent restriction.
The exhaust system should be inspected and cleaned a minimum of every 6 months with normal usage. The more the dryer is used, the more often you should check the
exhaust system and vent hood for proper operation.
EXHAUST DIRECTION
All dryers shipped from the factory are set up for rear exhausting. However, on electric dryers, exhausting can be to the right or left side of the cabinet or the bottom of the dryer. On gas dryers, exhausting can be to the right side of the cabinet or the bottom of the dryer. Directional exhausting can be accomplished by installing Exhaust Kit, P/N 131456800, available through your parts distributor. Follow the instructions supplied with the kit.
EXHAUST DUCT LOCATING DIMENSIONS
SAME AS OTHER SIDE
5 7/8"
(15 cm)
13 1/2" | 4 3/8" |
(11 cm) | |
(34 cm) |
|
3 3/4" |
|
(9.5 cm) | 3 3/4" |
| (9.5 cm) |
GAS SUPPLY REQUIREMENTS
Replace copper connecting pipe that is not
1.Installation MUST conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition).
2.The gas supply line should be of 1/2 inch (1.27 cm) pipe.
3.If codes allow, flexible metal tubing may be used to connect your dryer to the gas supply line. The tubing MUST be constructed of stainless steel or
4.The gas supply line MUST have an individual shutoff valve.
5.A 1/8 inch (0.32 cm) N.P.T. plugged tapping, accessible for test gauge connection, MUST be installed immediately upstream of the gas supply connection to the dryer.
6.The dryer MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures in excess of 1/2 psig (3.45 kPa).
7.The dryer MUST be isolated from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 kPa).