2 Troubleshooting Procedures | 2.3 Power Supply Troubleshooting |
Procedure 2 Error Code Check
If the power supply microprocessor detects a malfunction, the DC IN icon blinks orange. The blink pattern indicates an error as shown below.
Start | Off for 2 seconds |
Error code (8 bit) |
|
“1” | On for one second |
“0” | On for half second |
Interval between data bits | Off for half second |
The error code begins with LSB (Least Significant bit).
Example: Error code 11h (Error codes are given in hexadecimal format.)
Check 1 Convert the DC IN icon blink pattern into the hexadecimal error code and compare it to the tables below. Then go to Check 2.
| Table |
|
|
Error code | Where Error occurs |
1*h | DC IN (AC Adapter) |
2*h | 1st battery |
3*h | 2nd battery |
4*h | S3V output |
5*h | E5V output |
6*h | E3C output |
|
|
7*h | |
8*h | |
9*h | PPV output |
A*h | PTV output (CH0) |
B*h | |
C*h | PGV output |
D*h | |
E*h | PTV output (CH1) |
F*h | - |
[CONFIDENTIAL] | TECRA S3 Maintenance Manual |