4 Replacement Procedures 4.23 FP board
4-56 [CONFIDENTIAL] TECRA S3 Maintenance Manual (960-532)

4.23 FP board

Removing the FP board
To remove the FP board, follow the steps below and refer to Figure 4-40.
1. Peel off the glass tape (back of the middle assembly).
2. Remove the following screws and FP board.
M2×3S S-FLAT HEAD screw ×2
3. Disconnect the FP cable from the connector CN950 on the FP board.
Figure4-40 Removing the FP board
FP cable FP board
M2×3S S-FLAT HEAD
Glass tape
CN950