Appendices

Appendix J Maintenance of TOSHIBA RAID

Table J-1 List of Command (2/2)

LBA (Logical Block Address): First sector address caused an error.

Sector Count: Number of sectors transmitted from the address indicated by LBA.

STATUS: Status of command. The lowest bit becomes “1”, when an error occurs.

Error: Content of error. It indicates that an error occurs when the object bit is “1”.

Bit7:ICRC

Indicates that a CRC error occurs on the transmission bus (SATA) between Host and HDD.

Bit6:UNC

Indicates that an uncorrectable (media) error occurs. Bit2:ABRT

Indicate that the command aborts.

J-6

[CONFIDENTIAL]]

TECRA S3 Maintenance Manual (960-532)

Page 448
Image 448
Toshiba S4 manual Confidential