3.3 Check of the RAID configuration

3 Tests and Diagnostics

TOSHIBA RAID / RAID Information Display Rev xx.xx.xxxx Copyright(c) 2005 TOSHIBA CORPORATION. All Rights Reserved.

 

Level

Status

Capacity

 

LD0

RAID-1

DEGRADE

xxGB

 

 

Write cache

: Enable

 

 

MBR Protection

: Disable

 

 

S.M.A.R.T

: Enable

 

Port

Assgn

Status

Size

Model

Rev

0

LD0-0 ONLINE

xxGB

FUJITSU-------------

xxxxxxx

1

LD0-1

FAILED

xxGB

FUJITSU-------------

xxxxxxx

<RAID : not OPTIMAL >

3.3.3.1RAID : OPTIMAL

When RAID is “OPTIMAL” (Both the two drives are normal), it is judged that RAID configuration is normal. There are the following reasons why the repair is requested.

Abnormal noise of the motor from the HDD:

Refer to the 2.5-HDD trouble shooting in Chapter 2, Troubleshooting Procedures.

Access to the HDD is very slow :

Display the drive log by using Independent Utility of the DIAGNOSTIC PROGRAM. Check if ten or more continual logs of the message indicating retry such as “Write Error occurred, Retry the command.” or “Other Read Error occurred, Retry the command.” is recorded in the drive log of either HDD. If recorded, the drive is failed and should be repaired. Refer to Independent Utility in Appendix J.

In the other case above mentioned, it is judged that the MB side fails.

TECRA S3 Maintenance Manual (960-532)

[CONFIDENTIAL]

3-13

Page 131
Image 131
Toshiba S4 manual RAID Optimal, Abnormal noise of the motor from the HDD, Access to the HDD is very slow