4.30 Fluorescent Lamp

4 Replacement Procedure

4.30 Fluorescent Lamp

This system uses LCD modules from the following suppliers. The procedure for replacing the fluorescent lamp is different for each LCD module. Refer to the appropriate procedure.

Type

Part No.

Supplier

Section

 

 

 

 

15.0-inch (XGA)

G33C00030110

LG Philips

4.30.1

 

 

 

 

 

G33C0002Y110

SHARP

4.30.2

 

 

 

 

 

G33C0002W110

Samsung

4.30.3

 

 

 

 

15.0-inch (SXGA+)

G33C0001X210

LG Philips

4.30.4

 

 

 

 

NOTE: - When working with a LCD module, always use a flat, grounded table.

-Handle the backlight unit in the environment without dust, such as on the clean bench. Keep the worktable free from any screws or other material that may scratch the LCD surface.

-Use an anti-static or protective sheet.

-When replacing the FL unit, cover with a finger protector or similar to prevent soiling or scratching the LCD panel.

-Be careful when handling the lamp. Excessive force may break the lamp.

-Be careful not to soil or deform the lamp reflector.

-Make sure that the power of the LCD module is turned off before connecting or disconnecting cables and connectors.

TECRA S3 Maintenance Manual (960-532)

[CONFIDENTIAL]

4-75

Page 317
Image 317
Toshiba S4 manual Fluorescent Lamp Replacement Procedure, Type Supplier Section