2 Troubleshooting Procedures | 2.6 HDD Troubleshooting |
Procedure 4 Diagnostic Test Program Execution Check
The HDD test program is stored in the Diagnostics Disk. Perform all of the HDD tests in the Hard Disk Drive Test. Refer to Chapter 3, Tests and Diagnostics, for more information about the HDD test program.
If an error is detected during the HDD test, an error code and status will be displayed. Replace the HDD with a new one following the instructions in Chapter 4, Replacement Procedures. The error codes and statuses are listed in Table
| Table |
|
|
Code | Status |
|
|
01h | Bad command error |
|
|
02h | Address mark not found |
|
|
04h | Record not found |
|
|
05h | HDC not reset |
|
|
07h | Drive not initialized |
|
|
08h | Overrun error (DRQ) |
|
|
09h | DMA boundary error |
|
|
0Ah | Bad sector error |
|
|
0Bh | Bad track error |
|
|
10h | ECC error |
|
|
11h | ECC recover enable |
|
|
20h | HDC error |
|
|
40h | Seek error |
|
|
80h | Time out error |
|
|
AAh | Drive not ready |
|
|
BBh | Undefined error |
|
|
CCh | Write fault |
|
|
E0h | Status error |
|
|
EEh | Access time error |
|
|
DAh | No HDD |
|
|
[CONFIDENTIAL] | TECRA S3 Maintenance Manual |