4.30 Fluorescent Lamp | 4 Replacement Procedure |
4.30.2 Replacing the
CAUTION: When replacing the fluorescent lamp, wear finger covers or gloves to avoid contaminating or damaging the LCD panel. Be careful not to let dust or other foreign substance into the module.
Removing the
To remove the
1.Turn the LCD module face down, and remove the protection cover SC (A), protection cover G (B) and two fixing tapes (C) and (D).
CAUTION: 1) Be careful not to damage the TCP and chip.
2)Discard the tapes(A, C, D) removed.
3)The protection cover G (B) is reused. Do not peel off the place sticked to the bezel.
(D)
(A)
(B)
(C)
Figure 4-65 Replacing Sharp fluorescent lamp (XGA) (1)