Appendix J Maintenance of TOSHIBA RAID

Appendices

(2) Check if it is caused by an operation miss or is a failure.

To check if the cause of failure of Port1 is an operation miss or not, analyze the Drive Log of Port0.

1.In [REDUNDANT] of Port-0, find a log of “Fail this drive” message by PgUp and

PgDn key.

2.If no message of “Fail this drive” message, it is judged that the second HDD is removed without the operation of removal by TOSHIBA RAID console and installed again.

(3)How to change the status to OFF LINE

Release the status of “Fail”, using the menu of [Force OFFLINE]. This HDD is not necessary to be repaired.

TECRA S3 Maintenance Manual (960-532)

[CONFIDENTIAL]]

J-7

Page 449
Image 449
Toshiba S4 manual PgDn key