4.24 LCD unit/FL inverter 4 Replacement Procedures
TECRA S3 Maintenance Manual (960-532) [CONFIDENTIAL] 4-61
7. Carefully lift up the top of the LCD unit to access the LCD cable.
NOTE: When lifting up the top of the LCD unit, hold the corners of the LCD unit. The
top edge of the LCD unit is sensitive area.
8. Remove the glass tape securing the LCD cable.
9. Disconnect the LCD cable and remove the LCD unit.
CAUTION: When removing the LCD cable, be careful not to damage the connector.
Figure 4-44 Removing the LCD unit (2)
LCD cable
Glass tape