3 Tests and Diagnostics 3.3 Check of the RAID configuration
3-16 [CONFIDENTIAL] TECRA S3 Maintenance Manual (960-532)
FAIL for one drive is displayed
One drive in the “RAID-1”is failed and degraded. This may look like failure by
wrong operation. Specify the reason by using Independent Utility.
TOSHIBA RAID / RAID Information Display Rev xx.xx.xxxx
Copyright(c) 2005 TOSHIBA CORPORATION. All Rights Reserved.
Level Status Capacity
LD0 RAID-1 DEGRADE xxGB
Write cache : Enable
MBR Protection : Disable
S.M.A.R.T : Enable
Port Assgn Status Size Model Rev
0 LD0-0 ONLINE xxGB FUJITSU----------------- xxxxxxx
1 LD0-1 FAILED xxGB FUJITSU----------------- xxxxxxx
< RAID : not OPTIMAL >