3Installation

Refer to the nearest Authorised Service Agent for installation of your product. CPreparation of location and electrical installation for the product is under

customer’s responsibility.

B Installation and electrical connections must be carried out by a qualified personnel.

A Prior to installation, visually check if the product has any defects on it. If so, do not have it installed. Damaged products will cause risks for your safety.

Appropriate installation location

• Install the product in an environment which has no risk of freezing and is in a stable and level position.

• Operate your product in a well ventilated, dust-free environment.

• Do not block the air ducts in front of and under the product with materials such as long pile rugs and cupboard plinths.

• Do not place your product on a long pile rug or on similar surfaces.

• Do not install the product behind a door with a lock, sliding door or a hinged door which can strike the product.

• Once the product is installed, it should stay at the same place where its connections have been made. When installing the product, make sure that the rear wall of it does not touch anywhere (tap, socket, etc.) and also pay attention to install the product at a place where it will stay permanently.

BDo not place the product on top of the power cable.

Keep at least 1.5 cm distance to walls of other furniture.

Under Counter Installation

Leave at least 3 cm of space between the side and rear walls of the machine and the walls of the counter/cupboard when installing your machine under a counter or in a cupboard. Never use the tumble dryer without top plate.

Ventilation hose and connection (for products equipped with an outlet vent)

Ventilation hose assures exhausting of the air from inside the machine.

Vented dryer has 1 air outlet.

Stainless sheet metal or aluminum pipes can be used instead of the hose. The diameter of the pipe to be used should be minimum 10 cm.

Maximum hose and pipe lengths are given in the table below.

 

 

Hose

Pipe

 

Maximum length

4 m

5 m

 

1 elbow 45°

-1.0 m

-0.3 m

 

1 elbow 90°

-1.8 m

-0.6 m

 

1 elbow 90° short

 

-2.7 m

 

1 wall passage

-2.0 m

-2.0 m

 

C Each elbow and

other passages

 

should be subtracted from the above

 

maximum length.

 

 

To connect a ventilation hose;

 

1.Connect the air outlet hose to the hose spacer piece by turning it anti- clockwise.

2.Make the hose passages as shown

below.

CExhaust of humid air from the dryer into the room is inconvenient. It may damage the walls and furniture in the room.

CThe ventilation hose can be routed outdoors via a window or it can be connected to an air outlet in the wall (see diagram below).

CAir outlet hose must be extended directly to the outdoors. There must be a small number of elbows as not to hinder air ventilation.

CTo prevent water accumulation in the hose, make sure that it is not folded on the floor.

8

EN

Image 8
Contents Dvtc 60 W Explanation of symbols Read this manual prior to initial operation of the productInstallation Fluff filterYour Dryer Overview Technical Specifications Important safety information General safetyChildren’s safety Intended useUnder Counter Installation InstallationAppropriate installation location Adjusting feet First useDisposing of packaging material Transportation of the machineElectrical Connection İnitial Preparations For Drying Things to be done for energy savingLaundry suitable for drying in the machine Laundry unsuitable for drying in the machinePreparing laundry for drying Correct load capacityHome articles GarmentsLow temperature Start/Pause/Cancel buttonSelecting a Programme and Operating Your Machine On/Off buttonTimer programmes Preparing the machineMain programmes Anti-creasingProgramme selection and consumption table Timer follow-up indicator Auxiliary functionStarting the Programme Changing the programme after the programme has startedEnding the programme through cancelling End of programmeQuick instructions for daily use Maintenance and cleaning Fluff filterSolution suggestions for problems Door Reversal Guarantee What is covered?What is not covered? Important notesService Service once the manufacturers guarantee has expiredRepublic of Ireland UK Mainland & Northern Ireland25 EN 26 EN 27 EN 28 EN