Asko TL751XXL operating instructions Dryer airflow

Page 30

Installation instructions

Step 6. Dryer airflow

Effective dryer operation requires appropriate dryer airflow.

The adequacy of the airflow can be measured by evaluating the static pressure.

Static pressure in the exhaust duct can be measured with a manometer, placed on the exhaust duct approximately 1 ft. (30.5 cm) from the final outlet.

Static pressure in the exhaust duct should not exceed 7.6 mm water column.

The dryer should be checked while the dryer is running with no load.

Measuring Static pressure

Manometer

Exhaust Duct

MAXIMUM STATIC PRESSURE IN WATER COLUMN

7.6mm

Step 7. Additional instructions for installation of your dryer in a manufactured or mobile home

The following instructions are applicable to installations of the dryer in a manufactured or mobile home.

Any installation in a manufactured or mobile home must comply with the Manufactured

Home

Construction and Safety Standards and local codes and ordinances.

If you are uncertain whether your proposed installation will comply with these standards, please contact a service and installation professional for assistance.

The following instructions apply to any installation of the dryer in a manufactured or mobile home:

1)The electrical connection for an electric dryer must be a 4-wire connection. More detailed information concerning the electrical connection is provided at the manual section entitled Electrical Requirements for Electric Dryer.

2)To reduce the risk of combustion and fire, the dryer must be vented to the outside.

3)Electric dryers may be vented to the outside using the back, left, right, or bottom panel.

4)The dryer exhaust duct must be affixed securely to the manufactured or mobile home structure, the exhaust duct must be made of a material that will resist fire and combustion, and it is recommended that you use a rigid or flexible metal pipe.

5)DO NOT connect the exhaust duct with any other exhaust duct, vent, or chimney.

6)Make sure the dryer has adequate access to outside fresh air to ensure proper operation. The opening for outside fresh air must be at least 25 sq. inches (163 cm2).

7)It is important that the clearance of the duct from any combustible construction be at least 2 inches (5 cm), and, when venting the dryer to the outdoors, the dryer can be

29

Customer Care Center

1-800-898-1879

www.askousa.com

Image 30 Contents
Operating Instructions Tumble dryer Asko TL751 XxlwPage Contents Before using your machine for the first time Do not tumble dryImportant safety instructions Grounding instructionRefer to Electrical requirements Packing material RecyclingInterrupting a program Child safety Do not allow children to play with the Tumble dryerAccessories Dryer Rack Description of the tumble dryerWithout manufacturers notice Front panel Advice and tips before you tumble dry Have the clothes been spun?Laundry labels Operating instructions Manual Dry Preset Program Settings Sensor Dry Preset Program SettingsWhen using Air Dry Manual Dry programsProgramed settings Options guide WearCleaning the lint filter Loading or removing laundryDry program finished Dry Sensor Selecting SettingsSignal TempSelecting Options Rack DryMore Time / Less Time Anti-crease Damp SignalDelay Start Child LockCare and maintenance instructions Cleaning the door and its openingTroubleshooting guide Troubleshooting TipProblem There Is Lint On My Clothes Problem There Is Static In My Clothes After DryingProblem The Drying Time Is Not Consistent Problem It Takes Too Long For My Clothes To Dry Problem My Clothes Are WrinkledProblem My clothes are shrinking Technical data Technical informationWrite to us at Service and guaranteeAsko Appliances Inc. will not pay for Or contact ourLength of warranty Two-Year Full Installation instructions Positioning the tumble dryerCloset Side View Connecting the exhaust system Clean old ducts before installing this dryerAlternate exhaust directions Confirming heat source operation Electrical plug connectionsPreparation of the dryer Confirming heat source in electric dryersDryer airflow 120V/240V, 60 Hertz, 3-wire installation Important WarningInstructions for grounding of your electric dryer Wire direct Electrical requirementsWire connection Direct wire Electrical requirements Option 1 4-wire connection with a power supply cord Option 2 3-Wire connection with a power supply cord Option 3 Optional 3-wire connectionRecommended User-maintenance instructions Exhaust and dryer maintenanceExhaust requirements and instructions Exhaust requirements and maintenance Cleaning the lint screenReversing the door Door hangingFollowing these instructions Select a program Turn on the main power buttonQuick guide Press the Start/Stop button Drying program finished
Related manuals
Manual 41 pages 59.33 Kb