English

4-Wire Cord Connections

Green Ground

Green Power Cord

Brass Terminal

Screw

Ground Wire

Terminal Block

Green Neutral

Ground Wire

Red

Power Cord

Strain Relief

Mounting Bracket

Black

Tighten Nut to

These Threads

Nut

1.Removethe screws securingthe terminal block accesscoverand the strain relief mounting bracketlocatedon the backof the dryer upper corner.

2.Install a UL approvedstrain relief into the power cord entry hole of the mounting bracket. Finger tighten the nut only at this time.

3.Removethe green neutral ground wire from the green ground screw located abovethe terminal block.

TypicalConductor

Receptacle

Black 240V

White Neutral

Typical4

Red 240V

ConductorCord

Green Ground

11

Image 12
Contents Electric Dryer Seche-linge Genesis Secadora Electrica English You will need it to obtain warranty service Tables Of Contents Installation Instructions Exhaust System Connections Materials Location of Your Dryer CorrectIncorrect Electrical Connections Wire Cord Connections USA only English English Power On/Off Button Start/Pause ButtonWrinkle Care Button Cycle Signal Button Timed/Cycles ButtonMore Time & Less Time Button Cycles ButtonFunction Light Indicator Preparations before dryingLoad clothes into dryer Rack Dry cycleMore Dry Press Temp button to set a suitable drying temperature Timed Dry cycle Other Features Normal Operating Sounds Care and Cleaning Guide Troubleshooting Limited Warranty