GSI Outdoors PNEG-1447 manual Rear discharge switch open to show mercury switch

Page 52

Lower Junction Box, Meter Roll Motor Conduit, Rear Discharge Conduit

 

 

Meter roll speed sensor.

 

 

 

 

16

 

 

 

 

Rear discharge switch conduit at rear left

 

 

 

 

gusset.

17

 

 

 

 

 

 

18

 

 

 

 

 

 

19

 

 

 

 

 

 

2

 

 

 

 

 

 

1

 

 

 

 

 

 

11

 

 

 

 

 

 

1

 

 

 

 

7

 

Rear discharge switch (open to show mercury switch).

7

11

1

 

 

20

 

 

 

 

 

 

8

 

 

 

 

 

 

 

24

 

 

 

 

9

 

 

 

 

 

 

 

23

 

 

 

 

21

22

 

 

 

 

 

 

 

 

 

 

ITEM No.

DESCRIPTION

 

PART No.

 

 

 

 

 

 

 

 

 

 

1

SEALTITE PVC 3/8"

 

FH-7038

 

 

 

2

CONNECTOR PVC 3/8" 45' W/NUT

 

F-6913

 

 

 

3

SEALTITE PVC 3/4"

 

FH-7063

 

 

 

4

STRAIGHT PVC W/LOCKNUT 3/4"

 

FH-7053

 

 

 

5

FITTING COMPRESSION 3/4-TO BOX

 

D03-0199

 

 

 

6

CONDUIT 3/4" EMT

 

D03-0086

 

 

 

7

ENCLOSURE 4x4x2.5 WHITE PVC

 

FH-6972

 

 

 

8

CONNECTOR 1/2"

 

FH-1310

 

 

 

9

WIRE 18/2 TYPE SJOW-A BLACK

 

WR-182SJOWA

 

 

 

10

RDCR 3/4"X1/2"HEX BUSHING

 

D07-0028

 

 

 

11

ELBOW 3/8" 90 DEGREE PVC W/NUT

 

FH-7050

 

 

 

12

CONNECTOR 3/8" LIQUID-TITE TO 1/2" EMT

 

D03-0060

 

 

 

13

CONNECTOR 1/2" EMT COMPRESSION

 

D03-0054

 

 

 

14

CONDUIT 1/2" EMT METALLIC

 

D03-0057

 

 

 

15

CONNECTOR 1/2" EMT COMPRESSION

 

D33-0002

 

 

 

16

SPEED SENSOR BOX BRACKET

 

D01-0462

 

 

 

17

SCR METER ROLL SPEED SENSOR

 

D01-0527

 

 

 

18

DISCONNECT .187 FEM

 

HH-7046

 

 

 

19

METERING ROLL TIMING GEAR ASSB

 

D01-0687

 

 

 

20

DISCHARGE SWITCH MOUNTING PLATE

 

D01-1105

 

 

 

21

COVER ALUMINUM, CONDUIT BODY

 

TFC-0075

 

 

 

22

CLIP, MERCURY SWITCH

 

SPD-2098

 

 

 

23

MERCURY SWITCH

 

D03-0010

 

 

 

24

CONDUIT BODY, LL TYPE

 

D03-0375

 

 

 

 

 

 

 

 

 

PNEG-1447

53

Image 52
Contents 1200S Network Series Portable Dryers Table of Contents PNEG-1447 Right side Left side FrameRight front corner of frame Left rear corner of frameCenter cross ties Frame, Auger Trough, & Hopper Bulkheads 11a Meter Rolls and Their Placement in the Dryer Metering Rolls and their placement in the dryerPlenum Closure Door ANGLE, RH Inside Plenum Screens, Plenum Closure Doors Meter Roll Upper Shield Assembly Close up of of meter roll upper shield assemblyOutside Screens / Meter Roll Access Door Meter roll access doorPlenum Divider Clean out door handle mechanism Clean out door hinge Clean Out DoorsFront and rear handle mechanisms rear shown in photo Linkage BAR Weldment Front End Panels / Fan Support / grill guards Rear End Panels / Rear Access Door Rear access door outside Rear access door insideFront Ladder Assembly Rear Ladder Assembly Bottom Auger Rear Discharge Box Auger bearing 12 13 14Top Auger with wet bin switch paddle end Top Auger With Wet Bin AssemblyTop Auger fill end Top Auger With Wet Bin Assembly BottomAuger Drive Bottom auger and metering roll drive guard Belt guard upper mount Top Auger DriveTop Auger drive components Top Auger belt guard cover Top Auger motor and motor mount Metering Roll Drive Front meter roll bearing Rear meter roll bearing Fan Heater housing assembly Fan Heater Housing AssemblyBurner support and collector cup 36& 40 burner support and collector cupWRAPPER, 28 FAN Heater Fan Motor, Motor Mount, & Fan Blade Fan motor and motor mount Fan blade and bushingAir Mixer Assemblies Air mixer assemblies 36 air mixer shown in photoBurner housing high limit switch Fan heater burner assemblyFlame Probe, Ignitor, Vaporizer Coil, and Burner Assemblies Items 9 and 10 are used in LP Fan/Heaters only40 &42 Fan heater burner assembly 26 & 28 Vaporizer coil connection and adjustment brackets 26 & 28 Fan heater LP pipe train assemblyLP Pipe Train Assemblies NIPPLE, 3/4 Close SCH Fan heater LP pipe train assembly Vaporizer coil connection and adjustment bracketsNumber LP pipe train assemblies NIPPLE, Close 26 & 28 Fan heater NG pipe train assembly NG Pipe Train AssembliesFan heater NG pipe train assembly 12 13 2 4 740 & 42 Fan heater NG pipe train assembly 11 12 2 4 72812hp THF-3241 3612hp 2813 THF-3242 3615hp 3281 Fan Heater Orifices4025hp 3438 THF-3058 LP Supply Line VALVE, 1/4 NPT 250 PSI ReliefNG Supply Line Valve 2 1/2 NPT Elect ShutoffRight & Left Grain and Plenum High Limits Upper plenum high limit thermostatSealtite PVC 3/8 Lower junction box right Lower junction box left Meter roll motor conduit connectionRear discharge switch open to show mercury switch Upper Juntion Box, Top Auger Motor Conduit, & Operator Light Air Switch Assembly Network Control Box 19bFan Heater Electrical Box Fan Heater control box and electrical componentsControl Box Control Panel Network control panel frontControl Box Control Panel Inside Lower Control Box Back Panel Upper control box power distrbution panel Upper Control BoxUpper Control Box Component Part Numbers 220V 1Ph 208V 3Ph 220V 3Ph 440V 3Ph 575V 3PhNumber Description Circuit 1218S Part Number Upper Control Box Components Part Numbers 220V 1Ph 208V 3Ph 220V 3Ph 440V 3Ph 575V 3PhNumber Description Circuit 1222S Part Number Number Description Circuit 1226S Part Number Page GSI Group, Inc 1004 E. Illinois St Assumption, IL Phone Fax