The dryer is designed to be operated on a separate branch, polarized,
The
Grounding Information
The dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. The dryer is equipped with a cord having an
WARNING
This dryer is equipped with a
W036
WARNING
Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the dryer is properly grounded.
W038
Do not modify the plug provided with the dryer – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
NOTE: Have a qualified electrician check the polarity of the wall receptacle. If a voltage reading is measured other than that illustrated, the qualified electrician should correct the problem.
Do not operate other appliances on the same circuit when this appliance is operating.
Installation
WARNING
To reduce the risk of an electric shock or fire, DO NOT use an extension cord or an adapter to connect the dryer to the electrical power source.
W037
M
| 2 |
1 | 3 |
120±12 | 0 V.A.C | |
V.A.C | ||
| ||
| 120±12 | |
| V.A.C |
4
5
Plug cord into separately fused 15 Amp circuitDRY2.
DRY2022N
1L1
2Ground
3Neutral
4Neutral Side
5Round Grounding Prong
Figure 31
Step 8: Recheck Steps 1-7
Refer to Installer Checklist on the back cover of this manual and make sure that dryer is installed correctly.
Step 9: Check Heat Source
Electric Dryers
Close the loading door and start the dryer in a heat setting (refer to the Operation section). After the dryer has operated for three minutes, the exhaust air or exhaust pipe should be warm.
513220 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 23 |