Installation

3.Remove ground screw and save for use in Step 5. Remove wire and use in Step 6.

1

D697I

D697I

1Ground Screw

Figure 17

4.Use a strain relief and insert end of power cord through power supply hole.

D696I

Figure 18

5.Attach power cord ground (green) wire to rear bulkhead using ground screw removed in Step 3.

 

7

1

 

 

6

 

 

5

 

 

4

 

2

 

 

3

DRY1920N

DRY1920N

1White

2“L2” Terminal

3Black

4Green

5Red

6Neutral Terminal

7“L1” Terminal

Figure 19

6.Use the three screws from the accessories bag to attach the remaining power cord wires to the terminal block as follows:

a.Red wire to “L1” terminal.

b.Black wire to “L2” terminal.

c.White wire to Neutral terminal.

NOTE: When installing the white wire, loop the free eyelet end of the ground wire (removed in Step 3) and attach along with the white wire to the neutral (center) terminal on the terminal block.

7. Tighten all screws firmly.

IMPORTANT: Failure to tighten these screws firmly may result in wire failure at the terminal block.

8.Secure the strain relief to the power cord, or wires, where they enter the dryer cabinet.

9.Check the continuity of the ground connection before plugging the cord into an outlet. Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet.

10.Reinstall access cover and screw.

20

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

513220

Image 22
Contents Clothes Dryer Page What to do if YOU Smell GAS Contents Explanation of Safety Messages Safety InformationImportant Safety Instructions Safety Information Installation DimensionsAdditional Security Tools Installing the DryerBefore You Start Position and Level the DryerArea Description Free Standing/Alcove Installation Connect Dryer Exhaust System Failure to exhaust dryer properly will void warranty Exhaust DirectionExhaust System Maximum length of 4 in .2 cm diameter rigid metal ductMulti-Dryer Installation Exhaust Requirements Metered Models IllustratedVertical Exhaust Installation Gas Dryer Only Connect Gas Supply Pipe Feet Inches NumberElectric Dryer Only Connect Electrical Plug Grounding Information THREE-WIRE Connecting Power Cord with Three-Wire Plug Copper Wire OnlyConnecting Power Cord with Four-Wire Plug D697I Reinstall nine screws removed in Step Reverse Door, if DesiredElectric Dryer Wipe Out Inside of DryerPlug In the Dryer Gas DryerCheck Heat Source Recheck StepsElectric Dryers Gas Dryers Operation Instructions Clean Lint FilterOperation Load LaundryTo Insert Money Set Fabric SelectorInsert Coins or Card To Insert CardIndicator Lights Insert COINS/CARDCare of Your Dryer MaintenanceLubrication Lint FilterMotor Overload Protector For Energy ConservationTroubleshooting Dryer won’t startContact Information Alliance Laundry Systems Shepard Street Box Ripon, WIPage Page Installer Checklist