Installation
Gas Dryers
IMPORTANT: This operation is to be conducted by qualified personnel only.
To view the burner flame, remove the lower front panel of the dryer.
Close the loading door, start the dryer in a heat setting (refer to the Operation section). The dryer will start, the igniter will glow red and the main burner will ignite.
IMPORTANT: If all air is not purged out of gas line, gas igniter may go off before gas is ignited. If this happens, after approximately two minutes igniter will again attempt gas ignition.
IMPORTANT: If igniter does not light, make sure gas is turned on.
After the dryer has operated for approximately five minutes, observe burner flame through lower front panel. Adjust the air shutter to obtain a soft, uniform blue flame. (A lazy,
1.Loosen the air shutter lockscrew.
2.Turn the air shutter to the left to get a luminous
3.After the air shutter is adjusted for proper flame, tighten the air shutter lockscrew securely.
4.Reinstall the lower front panel.
WARNING
For personal safety, lower front panel must be in place during normal operation.
W046
After the dryer has operated for approximately three minutes, exhaust air or exhaust pipe should be warm.
1
2
6
3 4
5
|
|
| DRY2235N |
1 | Closed Position | 5 | 1/8 in. (3.1 mm) Pipe Plug |
2 |
| (For checking manifold pressure) | |
3 | Air Shutter Lockscrew | 6 | Open Position |
4Air Shutter
Figure 32
24 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 513220 |