J. PREOPERATIONAL TESTS

ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions.

1.Turn on electric power to the dryer.

a.Open ALL shut-off valves (for Gas Models and Steam Models ONLY)

2.Refer to the Operating Instructions for starting your particular model dryer.

a.Gas Models

1)When the dryer is first started (during initial start-up), the burner has a tendency not to ignite on the first attempt. This is because the gas supply piping is filled with air, so it may take a few minutes for this air to be purged from the lines.

NOTE: During the purging period, check to be sure that ALL gas shut-off valves are open.

NOTE: Gas dryers are equipped with a Hot Surface Ignition (HSI) system which has internal diagnostics. If ignition is not established within three times the heat circuit in the HSI module will "LOCK-OUT" until it is manually reset. To reset the HSI system, open and close the main door and restart the dryer.

2)A gas pressure test should be taken at the gas valve pressure tap of each dryer to assure that the water column pressure is correct and consistent.

NOTE: Water column pressure requirements (measured at the gas valve pressure tap)...

Natural Gas

--------- 3.5 - 4.0 Inches W.C.

L.P. Gas ------------

10.5 - 11.0 Inches W.C.

IMPORTANT: There is no regulator provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank), or an external regulator must be added to each dryer.

b.Steam Models

1)Check to insure that steam damper is functioning properly.

a)The steam damper should not "slam" (open or closed) when it reaches the end of (piston) travel. Additionally, the steam damper should not bind and/or stop during travel. If either of these conditions occur, the flow control must be adjusted. Refer to the illustration on page 34 for air adjustment instructions.

36

Image 40
Contents ML-78 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Section Important InformationSafety Precautions What to do if YOU Smell GASStandards SPECIFICATIONS/COMPONENT Identification SpecificationsSpecifications Component Identification Dryer Rear View Installation Procedures Location RequirementsUNPACKING/SETTING UP Dryer Enclosure Requirements Fresh AIR Supply Page Exhaust Requirements Not be Reduced Anywhere Down Stream of the Dryer Reduced Anywhere Down Stream of the Dryer Page Electrical Information MLG-78 Gas MLS-78 Steam Page Black Positive White Neutral Green Ground Page Electrically Heated Models only Page GAS Information Type of Gas Page Page Steam Information Operating Steam PressureSteam Damper System Compressed Air Supply Air Pressure Page Page Preparation for OPERATION/START-UP Preoperational Tests Page Preoperational Instructions Shut Down Instructions Service SERVICE/PARTS InformationParts Returning Warranty Cards Warranty InformationReturning Warranty Parts Page Routine Maintenance CleaningSteam Dryers Reversing Timer SPIN/DWELL Adjustments Timing LegendData Label LOCATION/INFORMATION Data LabelSerial Number Procedure for Functional Check Replacement Components SectionADC113029