Amana W10300459A Plan Vent System, Clamps, Exhaust, Recommended hood styles Acceptable hood style

Page 12

Clamps:

Use clamps to seal all joints.

Exhaust vent must not be connected or secured with screws or other fastening devices that extend into interior of vent and catch lint. Do not use duct tape.

 

Clamp

Exhaust:

 

Recommended hood styles.

Acceptable hood style.

B

C

 

4"

A

(102 mm)

 

4"

2½"

(102 mm)

(64 mm)

4"

 

(102 mm)

 

A.Louvered hood style

B.Box hood style

C.Angled hood style is acceptable

An exhaust hood should cap the vent to keep rodents and insects from entering the home.

Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).

Do not use an exhaust hood with a magnetic latch.

Improper venting can cause moisture and lint to collect indoors, which may result in:

Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.

Housecleaning problems and health problems.

Plan Vent System

Choose your exhaust installation type

Recommended exhaust installations

Typical installations vent the dryer from the rear of the dryer. Other installations are possible.

Standard exhaust installation with rigid metal vent

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions.

AB

A.Over-the-top installation (also available with one offset elbow)

B.Periscope installation

NOTE: The following kits for close clearance alternate installations are available for purchase. Please see the “Assistance or Service” section of the Dryer User Instructions.

Over-the-Top Installation:

Part Number 4396028

Periscope Installation (For use with dryer vent to wall vent mismatch):

Part Number 4396037 - 0" (0 mm) to 18" (460 mm) mismatch

Part Number 4396011 - 18" (460 mm) to 29" (737 mm) mismatch

Part Number 4396014 - 29" (737 mm) to 50" (1270 mm) mismatch

Special provisions for mobile home installations:

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

A

A.Dryer

B.Elbow

C.Wall

D.Exhaust hood

B

C

D

E

F

G

B

H

E. Clamps

F. Rigid metal or flexible metal vent

G.Vent length necessary to connect elbows

H.Exhaust outlet

12

Image 12
Contents Table of Contents Dryer Safety Tools and Parts Location RequirementsParts supplied Parts neededInstallation clearances Dryer DimensionsElectrical Requirements Minimum Required SpacingInstall Leveling Legs Excessive Weight HazardIf connecting by direct wire Electrical ConnectionIf your home has You will be Go to Connecting to Section Electrical ConnectionElectrical Connection Options Style 1 Power supply cord strain relief Style 2 Direct wire strain reliefWire connection Power supply cord CG F Wire connection Direct Wire Page Venting Requirements Vent MaterialRigid metal vent Flexible metal ventSpecial provisions for mobile home installations Plan Vent SystemClamps ExhaustInstall Vent System Complete InstallationLevel Dryer Connect VentReverse Door Swing Optional Reversible Large Side-Swing DoorReversible Super Wide Side-Swing Door Page 2009 12/09 All rights reserved