Page 4

Installation clearances:

The location must be large enough to allow the dryer door to open fully.

Minimum Required Spacing

 

 

3"*

14" max.*

(76 mm)

 

2

Dryer Dimensions

433/8"

151/4"

(387 mm)

(1102 mm)

433/8"

 

(1102 mm)

*26"

*273/4"

(660 mm)

(705 mm)

 

29"

 

(737 mm)

223/4"

(578 mm)

29"

(737 mm)

 

 

 

(356 mm)

48 in.*

 

18"*

 

 

(310 cm )2

 

(457 mm)

 

 

 

 

 

 

 

 

 

24 in.2 *

3"*

 

 

 

 

(155 cm )2

(76 mm)

1"

29"

1"

1"* 27¾"

 

 

(25 mm)

(737 mm)

(25 mm) (25 mm) (705 mm)

 

 

 

A

 

B

 

C

 

 

A. Recessed area

 

 

 

 

B. Side view - closet or confined

area

433/8"

(1102 mm)

*273/4"

(705 mm)

A

223/4" (578 mm) 433/8"

(1102 mm)

*273/4"

(705 mm)

29"

(737 mm)

C

B

133/4" (349 mm)

29"

(737 mm)

D

C. Closet door with vents

*Additional spacing recommended

Mobile home - Additional installation requirements

This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280).

Mobile home installations require:

■ Metal exhaust system hardware, which is available for purchase from your dealer.

A. Small opening side-swing door

B. Large opening side-swing door

C. Wide opening side-swing door

D. Wide opening hamper door

*Most installations require a minimum 5½" (140 mm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”

Minimum installation spacing for recessed area or closet installation

The dimensions shown following are for the minimum spacing allowed.

■ Additional spacing should be considered for ease of installation and servicing.

■ Additional clearances might be required for wall, door, and floor moldings.

■ Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer.

■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.

Electrical Requirements

It is your responsibility:

To contact a qualified electrical installer.

■ To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances.

The National Electrical Code requires a 4-wire power supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.

A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.

■ To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

Do not use an extension cord.

■ If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

4

Image 4
Contents Table of Contents Dryer Safety Tools and Parts Location RequirementsParts supplied Parts neededInstallation clearances Dryer DimensionsElectrical Requirements Minimum Required SpacingInstall Leveling Legs Excessive Weight HazardIf connecting by direct wire Electrical ConnectionElectrical Connection If your home has You will be Go to Connecting to SectionElectrical Connection Options Style 2 Direct wire strain relief Style 1 Power supply cord strain reliefWire connection Power supply cord CG F Wire connection Direct Wire Page Venting Requirements Vent MaterialRigid metal vent Flexible metal ventSpecial provisions for mobile home installations Plan Vent SystemClamps ExhaustInstall Vent System Complete InstallationLevel Dryer Connect VentReversible Large Side-Swing Door Reverse Door Swing OptionalReversible Super Wide Side-Swing Door Page 2009 12/09 All rights reserved