Installation clearances:
The location must be large enough to allow the dryer door to open fully.
Minimum Required Spacing |
|
| 3"* |
14" max.* | (76 mm) |
| 2 |
Dryer Dimensions
433/8" | 151/4" | |
(387 mm) | ||
(1102 mm) | ||
433/8" | ||
| (1102 mm) | |
*26" | *273/4" | |
(660 mm) | (705 mm) | |
| 29" | |
| (737 mm) |
223/4"
(578 mm)
29"
(737 mm)
|
|
| (356 mm) | 48 in.* |
|
18"* |
|
| (310 cm )2 |
| |
(457 mm) |
|
|
|
|
|
|
|
|
| 24 in.2 * | 3"* |
|
|
|
| (155 cm )2 | (76 mm) |
1" | 29" | 1" | 1"* 27¾" |
|
|
(25 mm) | (737 mm) | (25 mm) (25 mm) (705 mm) |
|
| |
| A |
| B |
| C |
|
| A. Recessed area |
|
| |
|
| B. Side view - closet or confined | area |
433/8"
(1102 mm)
*273/4"
(705 mm)
A
223/4" (578 mm) 433/8"
(1102 mm)
*273/4"
(705 mm)
29"
(737 mm)
C
B
133/4" (349 mm)
29"
(737 mm)
D
C. Closet door with vents |
*Additional spacing recommended
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280).
Mobile home installations require:
■■ Metal exhaust system hardware, which is available for purchase from your dealer.
A. Small opening
B. Large opening
C. Wide opening
D. Wide opening hamper door
*Most installations require a minimum 5½" (140 mm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”
Minimum installation spacing for recessed area or closet installation
The dimensions shown following are for the minimum spacing allowed.
■■ Additional spacing should be considered for ease of installation and servicing.
■■ Additional clearances might be required for wall, door, and floor moldings.
■■ Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer.
■■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
■■ Companion appliance spacing should also be considered.
■■ Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
Electrical Requirements
It is your responsibility:
■■ To contact a qualified electrical installer.
■■ To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA
The National Electrical Code requires a
A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.
■■ To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate
■■ Do not use an extension cord.
■■ If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
4