INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Location Requirements

Flat-blade screwdriver

#2 Phillips head screwdriver

Adjustable wrench that opens to 1" (25 mm) or hex-head socket wrench (for adjusting dryer feet)

Level

Wire stripper (direct wire installations)

Utlility knife

1/4" nut driver (recommended)

Vent clamps

Caulking gun and compound (for installing new exhaust vent)

Tin snips (new vent installations)

Tape measure Pliers

Parts supplied:

Parts package is located in dryer drum. Check that all parts are included.

4 Leveling legs

Parts needed:

Check local codes. Check existing electrical supply and venting, and read “Electrical Requirements” and “Venting Requirements” before purchasing parts.

Mobile home installations require metal exhaust system hardware, available for purchase from the dealer from whom you purchased your dryer. For further information, please reference the “Assistance or Service” section of the Dryer

User Instructions.

If using a power supply cord:

Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:

A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft. (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.

A UL listed strain relief.

You will need:

A location allowing for proper exhaust installation.

 

See “Venting Requirements.”

A separate 30 amp circuit.

If you are using power supply cord, a grounded electrical

 

outlet located within 2 ft. (610 mm) of either side of dryer.

 

See “Electrical Requirements.”

A sturdy floor to

support the total weight (dryer and load)

 

of 200 lbs. (90.7 kg). The combined weight of a companion

 

appliance should also be considered.

Level floor with

maximum slope of 1" (25 mm) under entire

 

dryer. (If slope is greater than 1" [25 mm], install Extended

 

Dryer Feet Kit, Part Number 279810.) If not level, clothes

 

may not tumble properly and automatic sensor cycles may

 

not operate correctly.

Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

3

Image 3
Contents Table of Contents Dryer Safety Parts needed Tools and PartsLocation Requirements Parts suppliedMinimum Required Spacing Installation clearancesDryer Dimensions Electrical RequirementsElectrical Connection Install Leveling LegsExcessive Weight Hazard If connecting by direct wireIf your home has You will be Go to Connecting to Section Electrical ConnectionElectrical Connection Options Style 1 Power supply cord strain relief Style 2 Direct wire strain reliefWire connection Power supply cord CG F Wire connection Direct Wire Page Flexible metal vent Venting RequirementsVent Material Rigid metal ventExhaust Special provisions for mobile home installationsPlan Vent System ClampsConnect Vent Install Vent SystemComplete Installation Level DryerReverse Door Swing Optional Reversible Large Side-Swing DoorReversible Super Wide Side-Swing Door Page 2009 12/09 All rights reserved