American Dryer Corp ML-55II Steam Damper Air System Connections, Air Requirements, Air Connection

Page 16

Steam Damper Air System Connections

The dryer is manufactured with a pneumatic (piston) damper system, which requires an external supply of compressed air. The air connection is made to the steam damper solenoid valve, which is located at the rear inner top area of the dryer just in front of the electric service relay box.

Air Requirements

COMPRESSED

AIR PRESSURE

AIR SUPPLY

 

 

 

 

 

Normal

80 psi

5.51 bar

Minimum Supply

70 psi

4.82 bar

 

 

 

Maximum Supply

90 psi

6.21 bar

 

 

 

Shaded areas are stated in metric equivalents

Air Connection

Air connection to system — 1/8” N.P.T.

No air regulator or filtration is provided with the dryer. External regulation/filtration of 80 psi (5.52 bar) must be provided. It is suggested that a regulator/filter gauge arrangement be added to the compressed air line just before the dryer connection. This is necessary to ensure that correct and clean air pressure is achieved.

Steam System Operation

The steam damper shown in Diagram 1, allows the coil to stay constantly charged eliminating repeated expansion and contraction. When the damper is opened, the air immediately passes through the already hot coil, providing instant heat to start the drying process. When the damper is closed, ambient air is drawn directly into the basket (tumbler), allowing a rapid cool down (Diagram 2).

Diagram 1 shows the damper in the heating (open) mode, allowing heat into the basket (tumbler).

Diagram 2 shows the damper in the cool down (closed) mode, pulling ambient air directly into the basket (tumbler) without passing through the coils.

Note

With the dryer off or with no air supply, the steam

!damper is in cool down mode as shown in Diagram 2.

Steam Damper Air Piston (Flow Control) Operation Adjustment

Although the steam damper operation was tested and adjusted prior to shipping at 80 psi (5.52 bar), steam damper operation must be checked before the dryer is put into operation. Refer to the previous page for instructions to check steam damper operation. If steam damper adjustment is necessary, locate the flow control valve and make the necessary adjustments as noted below.

14

American Dryer Corp.

113345-9

Image 16
Contents ML-55II Installation Manual Retain This Manual In a Safe Place For Future Reference Table of Contents Safety Precautions Coil failure due to improper pH level will void WarrantyWhat to do if You Smell Gas 113345-9SPECIFICATIONS/COMPONENT SpecificationsInstallation Procedures Component IdentificationLocation Requirements Dryer Front ViewUnpacking/Setting Up Dryer Enclosure RequirementsLeveling Dryer Allowances must be made For opening the control doorFresh Air Supply Requirements Exhaust RequirementsGeneral Exhaust Ductwork Information Horizontal VentingOutside Ductwork Protection Vertical VentingSingle Dryer Venting When the exhaust ductwork Hazard. The copper conductor wire/cable must be of properPasses through a wall, ceiling Or roof made of combustibleElectrical Service Specifications Single-Phase 1ø Wiring Connections/HookupGas and Steam Models only Electric Models OnlyPhase 3ø Wiring Connections/Hookup Electrically Heated Models OnlyGas Information Steam Information Piping/ConnectionsSteam Coil pH Level Steam Requirements High PressureInstallation Instructions 861.84 kPaSteam Damper Air Piston Flow Control Operation Adjustment Steam Damper Air System ConnectionsAir Requirements Air ConnectionPreparation For Operation/Start-Up Preoperational TestsPreoperational Instructions Shutdown InstructionsSERVICE/PARTS Information Warranty InformationRoutine Maintenance CleaningAdjustments LubricationProcedure for Functional Check of Replacement Microprocessor Controller Computer BoardFor Models with Fenwal Controls DSI Module Theory of OperationManual Reset Burner HI-LIMIT PhaseDual Timer Data Label InformationInstallation Fire Suppression SystemBefore You Start Water ConnectionsS. Theory Of Operation Electrical RequirementsTypical Water Supply Optional Manual Bypass System Reset S. DiagnosticsS. Diagnostics Messages S. Water Valve CheckADC 113345 9 12/01/04-6