Maytag MCE8000AY manual Diagnostic Codes RS Reset to Factory Default Conditions

Page 14

Troubleshooting Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing requires power.

Diagnostic Codes

rS Reset to Factory Default Conditions

Code

Description

Trigger

 

Action Taken

 

 

 

 

 

SOL

Start of list

 

 

 

1

Lower Dryer

If temperature > 200

Check for:

 

Thermistor

degrees for 2 minutes.

-

Clogged lint

 

Short Sensed

 

-

screen.

 

 

 

Restricted vent

 

 

 

 

system.

 

 

 

Failed thermistor

2

Lower Dryer

If the temperature is

Check for:

 

Thermistor

low with an increase of

-

Low ambient

 

Open Sensed

temperature expected,

 

temperature in

 

 

and no increase

 

room (Below

 

 

occurring after 3

 

50°F/10°C).

 

 

minutes.

-

Outside vent

 

 

 

 

damper is stuck

 

 

 

 

open in

 

 

 

 

wintertime.

 

 

 

Loose or open wire

 

 

 

terminals

3

Lower Dryer

Low for more than 1

Check for:

 

Door Circuit

second.

-

Loose or open

 

Failure

 

wire terminals in

 

 

 

Door Sense circuit.

4

Not Used

 

 

 

 

 

 

 

 

5

Not Used

 

 

 

 

 

 

 

6

Non Volatile

Problem Detected with

Disregard

 

Memory

integrity of parameters

 

 

 

 

stored in EEPROM

 

 

 

 

memory.

 

 

8

Stuck Button

A button sensed as

Check for:

 

 

pressed more than 75

- Run membrane

 

 

seconds, is assumed

pad check and

 

 

as stuck.

replace console

 

 

 

w/membrane pad if

 

 

 

necessary..

9

Not Used

 

 

 

 

 

 

 

 

10

Not Used

 

 

 

 

 

 

 

11

Upper Dryer

If temperature > 200

Check for:

 

Thermistor

degrees for 2 minutes.

-

Failed hi-limit

 

Short Sensed

 

 

thermostat on

 

 

 

-

steamer.

 

 

 

Failed thermal

 

 

 

 

fuse on heater.

 

 

 

Failed thermistor

12

Upper Dryer

If the temperature is

Check for:

 

Thermistor

low with an increase of

-

Low ambient

 

Open Sensed

temperature expected,

 

temperature in

 

 

and no increase

 

room (Below

 

 

occurring after 3

 

50oF/10oC).

 

 

minutes.

-

Check door vent

 

 

 

 

seals.

 

 

 

Loose or open wire

 

 

 

terminals on

 

 

 

steamer circuit.

13

Upper Dryer

Low for more than 1

Check for:

 

Door Circuit

second.

-

Loose or open

 

Failure

 

wire terminals

To restore Factory Default settings for the dryer controls, complete the following sequence within one (1) minute.

Step 1 From the Normal Program State, press the Signal (+) button and Time Adjust to enter the Diagnostic State from the upper or lower dryer keypad.

Step 2 Scroll to the “rS” display on the menu and press Signal (+). The number “004” appears on the display to indicate the number of remaining steps needed to complete the reset sequence.

Step 3 Open and leave open the Lower Dryer Door. The remaining step count decrements to “003” on the display.

Step 4 Press the Time Adjust and Time Adjust at the same time. The remaining step count decrements to “002” on the display.

Step 5 Press the Temperature and Time Adjust at the same time. The remaining step count decrements to “001” on the display.

Step 6 Close the Lower Dryer Door. The remaining step count decrements to “000” once the Factory Default settings have been restored. The "Power On Reset" sequence then executes.

The remaining step count resets to four and the invalid selection chime sounds when any of the following conditions occur:

A reset step is performed out of sequence.

An unexpected key combination is entered. The time window expires.

Opening the door to complete the first step marks the beginning of the time window.

This function does not clear either of the upper or lower dryer cycle counters. All other parameters stored in non- volatile memory are returned to the Factory Default values.

The Reset Utility functions the same regardless of which half of the keypad it is initiated from. Once the utility is initiated, all key combinations must be made from the same half of the keypad used to initiate the utility.

The Signal (-)key exits the Reset Utility and returns to the “rS” display on the main menu. Pressing the Signal (-)key any time prior to completion of the reset sequence cancels the sequence and then returns to the main menu.

14

16022785 Rev. 0

©2003 Maytag Appliances Company

Image 14 Contents
Neptune DC Web Site Telephone Number Customer Service Support CenterRecognize Safety Symbols, Words, and Labels Table of Contents Important Safety Information Gas Connection Information Electrical Service InformationAbout Ground Wires Electrical DryersImportant Safety Information Altitude Orifice Part Ft M Size # Number Testing for Gas LeaksGas Connection Extended Service Plan ServiceParts and Accessories PropaneE 8 0 0 Drying Center NomenclatureDrying Center Specifications Will not start or run Maytag Neptune Drying CenterWill Not Run Will Not Dry Gas ModelsNoisy and/Or Vibration Troubleshooting the Sensor-Dry circuitSystem Check Mode Rd**Read Sensor InputsSensor Display Menu Diagnostic CodesDL****Accessing Diagnostic Codes Sc***Upper and Lower Dryer Sub-system Check UtilitiesDiagnostic Codes RS Reset to Factory Default Conditions Code Description Trigger Action TakenCodes Visible To The Consumer Enter The Diagnostic Utilities MenuCancel the Read Sensor Display Function CS******View Cycle StatisticsMembrane Pad Continuity Checks Location Description Plug Number Pin NumberJ1A Relay Header Connections Connector Description NameDoor Hook Removal Lower Door Reversal/RemovalShaker Removal Console Removal Front Access Panel Removal Logic Board RemovalDisassembly Procedures Tumbler Drum Removal Heater Assembly Removal Relay Board Removal Blower and Motor RemovalWater Valve Removal Steamer Blower RemovalSteamer Heater Removal Appendix a Maytag Appliances Company 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev Appendix B Maytag Appliances Company 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev 16022785 Rev