Disassembly Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to unit before servicing.
11.Rotate motor counterclockwise approx. 45 degrees. Lift up on the back of the Motor and pull out of the Front Support.
Water Valve Removal
1.Disconnect power supply to unit.
2.Remove Console.
3.Remove the Front Panel.
4.Remove Hose on back of Water Valve.
5.Slide Water Valve Assembly toward front and remove.
Steamer Blower Removal
1.Disconnect power supply to unit.
2.Remove Console.
3.Remove the Front Panel.
4.Remove Hose on back of Water Valve.
5.Slide Water Valve Assembly toward front and remove.
6.Loosen screws securing Blower Assembly and remove.
7.Loosen screws on mounting plate and remove Blower Assembly.
©2003 Maytag Appliances Company | 16022785 Rev. 0 | 25 |