Maytag W10557650B Custom undercounter installation dryer only, Mobile home installations require

Page 11

Installation spacing for recessed area or closet installation

nAll dimensions show recommended and minimum spacing allowed.

nAdditional spacing should be considered for ease of installation and servicing.

nAdditional clearances might be required for wall, door, floor moldings, and dryer venting.

nAdditional spacing should be considered on all sides of the dryer to reduce noise transfer.

nFor closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

nCompanion appliance spacing should also be considered.

Custom undercounter installation (dryer only):

331/4"

(845 mm)

Recessed or closet installation – Stacked with stack kit:

12"

(305 mm)

3"

(76 mm)

661/4"

(1683 mm)

51/4"

3"

(133 mm)

(76 mm)

 

1"

1" (25 mm) (25 mm)

48in.2

(310 cm2)

24in.2

(155 cm2)

1"

233/8" (25 mm)

1" (594 mm) (25 mm)

Recessed or closet installation (dryer only):

Mobile home - Additional installation requirements:

This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile home construction and Safety, Title 24, HUD Part 280).

Mobile home installations require:

18"9"min (457(229mm))

3"

(76 mm)

48in.2

(310 cm2)

nMetal exhaust system hardware, available for purchase from your dealer.

nSpecial provisions must be made in mobile homes to introduce outside air into dryer. Openings (such as a nearby window) should be at least twice as large as dryer exhaust opening.

3"

3"

(76 mm)

(76 mm)

 

1"

1" (25 mm) (25 mm)

24in.2

(155 cm2)

11

Image 11
Contents W10557650B Use & Care GuideElectric Dryer Page Low Control Panel and FeaturesNormal Cycle Guide Timed DRY Cycles Items to dry Cycle Temperature SettingItems to dry Time Temperature Minutes Setting Cycle Guide Sensor DRY CyclesPress Temperature Using Your DryerClean the lint screen Press PowerPress Start to begin cycle Dryer CareSelect the desired cycle Moving Care Reinstalling the DryerNon-Use or Storage Care Parts supplied Installation RequirementsIf using a power supply cord Tools neededLocation Requirements Installation ClearancesMobile home installations require Custom undercounter installation dryer onlyRecessed or closet installation Stacked with stack kit Electrical Connection If connecting by direct wireElectrical Requirements It is your responsibilityFor direct wire installations Electric InstallationFor power supply cord installations Replace strain relief Power Supply Cord ConnectionRemove neutral ground wire Connect ground wire and neutral wireRemove center screw Connect remaining wiresConnect neutral wire Connect power supply cable wire Direct Wire ConnectionWire Direct Wire Connection Prepare your 4-wire cable for direct connectionPrepare your 3-wire cable for direct connection Venting Requirements VentingDetermine vent path Alternate installations for close clearancesPlan Vent System Special provisions for mobile homesConnect Vent Install Vent SystemLevel dryer Adjust leveling legsLevel Dryer Unusual Noise TroubleshootingIf you experience Possible Causes Solution Dryer OperationDryer Results Troubleshooting Page Page This limited warranty does not cover Maytag Laundry WarrantyU.S.A If you need replacement parts or to order accessoriesOur consultants provide assistance with