Maytag W10557650B manual Prepare your 3-wire cable for direct connection

Page 17

3-Wire Direct Wire Connection

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

1. Prepare your 3-wire cable for direct connection

1"

(25

mm)

 

3½"

(89

mm)

 

Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer may be moved if needed.

Strip 31/2" (89 mm) of outer covering from end of cable. Strip insulation back 1" (25 mm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape wire ends into hooks.

2. Remove center screw

B

Remove center terminal block screw (B).

3. Connect neutral wire

B

D

Place hooked end of neutral wire (white or center) (D) of direct wire cable under center terminal block screw (B), hook facing right. Squeeze hooked end together. Tighten screw.

4. Connect remaining wires

Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Replace the terminal block cover on the back of the dryer. Tighten strain relief nut. Now, go to“ Venting Requirements.”

17

Image 17
Contents W10557650B Use & Care GuideElectric Dryer Page Low Control Panel and FeaturesNormal Items to dry Time Temperature Minutes Setting Items to dry Cycle Temperature SettingCycle Guide Sensor DRY Cycles Cycle Guide Timed DRY CyclesClean the lint screen Using Your DryerPress Power Press TemperaturePress Start to begin cycle Dryer CareSelect the desired cycle Moving Care Reinstalling the DryerNon-Use or Storage Care If using a power supply cord Installation RequirementsTools needed Parts suppliedLocation Requirements Installation ClearancesMobile home installations require Custom undercounter installation dryer onlyRecessed or closet installation Stacked with stack kit Electrical Requirements If connecting by direct wireIt is your responsibility Electrical ConnectionFor direct wire installations Electric InstallationFor power supply cord installations Remove neutral ground wire Power Supply Cord ConnectionConnect ground wire and neutral wire Replace strain reliefRemove center screw Connect remaining wiresConnect neutral wire Wire Direct Wire Connection Direct Wire ConnectionPrepare your 4-wire cable for direct connection Connect power supply cable wirePrepare your 3-wire cable for direct connection Venting Requirements VentingPlan Vent System Alternate installations for close clearancesSpecial provisions for mobile homes Determine vent pathConnect Vent Install Vent SystemLevel dryer Adjust leveling legsLevel Dryer If you experience Possible Causes Solution TroubleshootingDryer Operation Unusual NoiseDryer Results Troubleshooting Page Page This limited warranty does not cover Maytag Laundry WarrantyU.S.A If you need replacement parts or to order accessoriesOur consultants provide assistance with