Maytag W10557650B Power Supply Cord Connection, Replace strain relief, Remove neutral ground wire

Page 14

Power Supply Cord Connection

Power supply cord strain relief:

1. Attach power supply cord to strain relief

4-Wire Power Supply Cord Connection

IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.

Locking Nut

A

B

C

Unscrew the strain relief (A) from the terminal block cover. Unscrew the strain relief nut (B) from the strain relief (A).

4-wire receptacle (NEMA type 14-30R)

Spade terminals with upturned ends

4-prong plug

Ring terminals

Put the power supply cord (C) through the strain relief nut (B), then the strain relief (A). Be sure that the wire insulation on the power supply cord is inside the strain relief.

2. Replace strain relief

A

B

C D

Replace strain relief (B) (with power cord [D] inserted) back into the terminal block cover (A). Connect locking nut to strain relief on inside of terminal block cover. Do not tighten strain relief nut (C).

If your outlet looks like this:

Power supply cord 4-wire receptacle (NEMA Type 14-30R):

Go to “4-Wire Power Supply Cord Connection” on this page.

If your outlet looks like this:

Power supply cord 3-wire receptacle (NEMA Type 10-30R):

Go to “3-Wire Power Supply Cord Connection” on page 15.

1. Remove neutral ground wire

F

A

B

Remove the neutral ground wire (F) located inside the dryer cabinet, behind the external ground conductor screw (A).

2. Connect ground wire and neutral wire

B

D

A

E

Connect ground wire (E) (green or bare) of power supply cord to external ground conductor screw (A). Tighten screw. Connect neutral wire (D) (white or center wire) of power supply cord under center screw (B) of the terminal block.

14

Image 14
Contents Use & Care Guide W10557650BElectric Dryer Page Low Control Panel and FeaturesNormal Cycle Guide Sensor DRY Cycles Items to dry Cycle Temperature SettingItems to dry Time Temperature Minutes Setting Cycle Guide Timed DRY CyclesPress Power Using Your DryerClean the lint screen Press TemperaturePress Start to begin cycle Dryer CareSelect the desired cycle Moving Care Reinstalling the DryerNon-Use or Storage Care Tools needed Installation RequirementsIf using a power supply cord Parts suppliedInstallation Clearances Location RequirementsMobile home installations require Custom undercounter installation dryer onlyRecessed or closet installation Stacked with stack kit It is your responsibility If connecting by direct wireElectrical Requirements Electrical ConnectionFor direct wire installations Electric InstallationFor power supply cord installations Connect ground wire and neutral wire Power Supply Cord ConnectionRemove neutral ground wire Replace strain reliefRemove center screw Connect remaining wiresConnect neutral wire Prepare your 4-wire cable for direct connection Direct Wire ConnectionWire Direct Wire Connection Connect power supply cable wirePrepare your 3-wire cable for direct connection Venting Venting RequirementsSpecial provisions for mobile homes Alternate installations for close clearancesPlan Vent System Determine vent pathInstall Vent System Connect VentLevel dryer Adjust leveling legsLevel Dryer Dryer Operation TroubleshootingIf you experience Possible Causes Solution Unusual NoiseDryer Results Troubleshooting Page Page Maytag Laundry Warranty This limited warranty does not coverU.S.A If you need replacement parts or to order accessoriesOur consultants provide assistance with