3. Connect remaining wires

Connect the other wires to outer terminal block screws. Tighten screws. Replace the terminal block cover on the back of the dryer. Tighten strain relief nut. Now, go to “Venting Requirements.”

3-Wire Power Supply Cord Connection

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

 

 

 

3-wire receptacle (NEMA

 

3-prong plug

type 10-30R)

 

 

 

 

 

 

 

 

Spade terminals with

Ring terminals

upturned ends

 

1. Remove center screw

B

Remove center terminal block screw (B).

2. Connect neutral wire

B

D

Connect neutral wire (white or center) (D) of power supply cord under center terminal block screw (B). Tighten screw.

3. Connect remaining wires

Connect remaining wires under outer terminal block screws. Tighten screws. Replace the terminal block cover on the back of dryer Tighten strain relief nut. Now, go to “Venting Requirements.”

15

Image 15
Contents W10557650B Use & Care GuideElectric Dryer Page Control Panel and Features NormalLow Cycle Guide Timed DRY Cycles Items to dry Cycle Temperature SettingItems to dry Time Temperature Minutes Setting Cycle Guide Sensor DRY CyclesPress Temperature Using Your DryerClean the lint screen Press PowerDryer Care Select the desired cyclePress Start to begin cycle Reinstalling the Dryer Non-Use or Storage CareMoving Care Parts supplied Installation RequirementsIf using a power supply cord Tools neededLocation Requirements Installation ClearancesCustom undercounter installation dryer only Recessed or closet installation Stacked with stack kitMobile home installations require Electrical Connection If connecting by direct wireElectrical Requirements It is your responsibilityElectric Installation For power supply cord installationsFor direct wire installations Replace strain relief Power Supply Cord ConnectionRemove neutral ground wire Connect ground wire and neutral wireConnect remaining wires Connect neutral wireRemove center screw Connect power supply cable wire Direct Wire ConnectionWire Direct Wire Connection Prepare your 4-wire cable for direct connectionPrepare your 3-wire cable for direct connection Venting Requirements VentingDetermine vent path Alternate installations for close clearancesPlan Vent System Special provisions for mobile homesConnect Vent Install Vent SystemAdjust leveling legs Level DryerLevel dryer Unusual Noise TroubleshootingIf you experience Possible Causes Solution Dryer OperationDryer Results Troubleshooting Page Page This limited warranty does not cover Maytag Laundry WarrantyIf you need replacement parts or to order accessories Our consultants provide assistance withU.S.A