Maytag W10445417B manual Location Requirements, Installation Clearances

Page 10

LOCATION REQUIREMENTS

Check code requirements. Some codes limit, or do not permit, installing dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

You will need:

nA location allowing for proper exhaust installation. See “Venting Requirements.”

nA separate 30 amp circuit.

nIf using power supply cord, a grounded electrical outlet located within 2 ft. (610 mm) of either side of dryer. See “Electrical Requirements.”

nFloor must support dryer weight of 115 lbs. (52 kg). Also consider weight of companion appliance.

nLevel floor with maximum slope of 1" (25 mm) under entire dryer. If slope is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. If not level, clothes may not tumble properly and automatic sensor cycles may not operate correctly.

nFor garage installation, place dryer at least 18" (460 mm) above floor. If using a pedestal, you will need 18" (460 mm) to bottom of dryer.

nThe dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

IMPORTANT: Do not operate, install, or store dryer where

it will be exposed to water, weather, or at temperatures below 45° F (7° C). Lower temperatures may cause dryer not to

shut off at end of sensor cycles, resulting in longer drying times.

Installation Clearances

DRYER DIMENSIONS

Front view:

233/8"

(594 mm)

331/4"

(845 mm)

Side view:

39"

(991 mm) 231/4"

(603 mm)

Back view:

For each arrangement, consider allowing more space for ease of installation and servicing, spacing for companion appliances, and clearances for walls, doors, and floor moldings. Space must be large enough to allow door to fully open. Add spacing on all sides of dryer to reduce noise transfer. If a closet door or louvered door is installed, top and bottom air openings

in door are required.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See “Venting Requirements.”

31/4"

(83 mm)

Power supply

cord/cable

27"

(686 mm)

Vent

113/4"

(299 mm)

10

Image 10 Contents
Use & Care Guide W10445417BElectric Dryer Page Normal Control Panel and FeaturesLow Items to dry Time Temperature Minutes Setting Items to dry Cycle Temperature SettingCycle Guide Sensor DRY Cycles Press Power Using Your Dryer Clean the lint screen Press TemperatureSelect the desired cycle Dryer CarePress Start to begin cycle Non-Use or Storage Care Reinstalling the DryerMoving Care Tools needed Installation RequirementsIf using a power supply cord Parts suppliedInstallation Clearances Location RequirementsCustom undercounter installation dryer only Mobile home Additional installation requirementsIt is your responsibility If connecting by direct wireElectrical Requirements Electrical ConnectionFor power supply cord installations Electric InstallationFor direct wire installations Connect ground wire and neutral wire Power Supply Cord ConnectionRemove neutral ground wire Replace strain reliefConnect neutral wire Connect remaining wiresRemove center screw Prepare your 4-wire cable for direct connection Direct Wire ConnectionWire Direct Wire Connection Connect power supply cable wirePrepare your 3-wire cable for direct connection Venting Venting RequirementsSpecial provisions for mobile homes Alternate installations for close clearancesPlan Vent System Determine vent pathInstall Vent System Connect VentLevel Dryer Adjust leveling legsLevel dryer Dryer Operation If you experience Possible Causes SolutionUnusual Noise Dryer Results Troubleshooting Page Page Maytag Laundry Warranty This limited warranty does not coverSi vous avez besoin de pièces de rechange If you need replacement parts or to order accessoriesOur consultants provide assistance with Nos consultants fournissent ’assistance pour