Maytag W10445417B manual Plan Vent System, Alternate installations for close clearances

Page 19

Plan Vent System

Choose your exhaust installation type

Recommended exhaust installation:

A

B

C

 

 

D

 

F

E

 

 

 

 

G

 

 

B

 

H

 

A. Dryer

F. Rigid metal or

B. Elbow

flexible

metal vent

G. Vent length necessary

C. Wall

to connect elbows

D. Exhaust hood

H. Exhaust outlet

E. Clamps

 

 

Alternate installations for close clearances:

Venting systems come in many varieties. Select the type best for your installation. A close-clearance installation is shown below. Refer to the manufacturer’s instructions.

Over-the-top installation (also available with one offset elbow)

Over-the-Top Installation Kit Part Number 4396028 for close clearance alternate installation is available for purchase. For ordering information, see “Assistance or Service.”

Special provisions for mobile homes:

Exhaust vent must be securely fastened to a noncombustible portion of mobile home and must not terminate beneath the mobile home. Terminate exhaust vent outside.

Determine vent path:

nSelect route that will provide straightest and most direct path outdoors.

nPlan installation to use fewest number of elbows and turns.

nWhen using elbows or making turns, allow as much room as possible.

nBend vent gradually to avoid kinking.

nUse as few 90° turns as possible.

Determine vent length and elbows needed for best drying performance:

Use the following “Vent System Chart” to determine type of vent material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified in “Vent System Chart.”

Exhaust systems longer than those specified will: ■■Shorten life of dryer.

■■Reduce performance, resulting in longer drying times and increased energy usage.

The “Vent System Chart” provides venting requirements that will help achieve best drying performance.

Vent System Chart

Number of

Type

Box/louvered

Angled

90° elbows

of vent

hoods

hoods

 

 

 

 

0

Rigid metal

90 ft. (27.4 m)

80 ft. (24.4 m)

 

 

 

 

1

Rigid metal

80 ft. (24.4 m)

70 ft. (21.3 m)

 

 

 

 

2

Rigid metal

70 ft. (21.3 m)

60 ft. (18.3 m)

 

 

 

 

19

Image 19 Contents
W10445417B Use & Care GuideElectric Dryer Page Normal Control Panel and FeaturesLow Items to dry Time Temperature Minutes Setting Items to dry Cycle Temperature SettingCycle Guide Sensor DRY Cycles Press Temperature Using Your DryerClean the lint screen Press PowerSelect the desired cycle Dryer CarePress Start to begin cycle Non-Use or Storage Care Reinstalling the DryerMoving Care Parts supplied Installation RequirementsIf using a power supply cord Tools neededLocation Requirements Installation ClearancesMobile home Additional installation requirements Custom undercounter installation dryer onlyElectrical Connection If connecting by direct wireElectrical Requirements It is your responsibilityFor power supply cord installations Electric InstallationFor direct wire installations Replace strain relief Power Supply Cord ConnectionRemove neutral ground wire Connect ground wire and neutral wire Connect neutral wire Connect remaining wires Remove center screw Connect power supply cable wire Direct Wire ConnectionWire Direct Wire Connection Prepare your 4-wire cable for direct connectionPrepare your 3-wire cable for direct connection Venting Requirements VentingDetermine vent path Alternate installations for close clearancesPlan Vent System Special provisions for mobile homesConnect Vent Install Vent SystemLevel Dryer Adjust leveling legsLevel dryer Dryer Operation If you experience Possible Causes SolutionUnusual Noise Dryer Results Troubleshooting Page Page This limited warranty does not cover Maytag Laundry WarrantyNos consultants fournissent ’assistance pour If you need replacement parts or to order accessoriesOur consultants provide assistance with Si vous avez besoin de pièces de rechange