Instruction Sheet | |
October 2013 | |
|
|
EEPROM Warning
Sense Line Open Warning Factory Cal Warning Keyboard Warning
Once a fault or warning is detected, the display will show a message describing the problem. Sensor Temperature Range:
Display:
Approvals:
RFI/EMI:
EN 301
EN 301
EN
EN 300 328 V 1.6.1
Hazardous Location Approvals
Intrinsic Safety:
Special Conditions of Use:
1.The 6081 enclosure is made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in zone 0. This applies to any
Intrinsically Safe installation, whether the Class, Division or Zone system is used.
2.Potential Electrostatic Hazard – The plastic antenna may present a potential electrostatic ignition hazard and must not be rubbed or cleaned with a dry cloth.
Intrinsically Safe,
Class I, Division 1
Groups ABCD/T4
Ta =
IP66
Class 1 Zone 0, AEx ia IIC T4
Ta =
IP66
Complies with FM standards:
FM3600:1998
FM3610: 2010,
FM3611: 2004
FM3810: 2005 ANSI/IEC 60529:2004
Class I, Division 1, Groups A/B/C & D
Class II, Division 1, Groups E/F& G
Class III
T4 Tamb :
Type 4x, IP66
CE 1180 II1G
Baseefa 10 ATEX 0149X
Ex ia IIC T4 Ga
Nonincendive, Class I,
Division 2, Groups ABCD/T4
Ta =
Class I, Division 2,
Groups A, B, D
Dust Ignition Proof
Class II, Division 2,
Groups F & G
T4 Tamb :
Environmental: The operating atmosphere of the transmitter must be consistent with the appropriate hazardous location certifications.