NOTE: Fuses and Wires

Regulations may require that the Model 833 be

!

fused. If installing a fuse, use a 10A fuse wired with

1.5mm or equivalent wire. The voltage drop across the fuse, its holder, and connectors must be less than 1% of the nominal system voltage.

Discharge Adjustments

Table 3 lists the voltages per cell under load that correspond to an empty indication on the gauge (lockout point).

Table 3. Discharge Adjustment Settings

Setting

Volt/Cell at Empty

K1.57

L1.63

M1.68

N1.73 (factory setting)

O1.78

P1.82

Q1.84

R1.86

S1.89

T1.91

U1.93

11

Image 13
Contents Read Instructions Carefully ModelSafety Instructions Table of Contents 833RB Vvvv Model EncodementZzzz Electrical Operating Range Technical SpecificationsOperating Current Relay Contact RatingsMechanical Display ResolutionHardware Kit Panel CutoutEnvironmental TemperatureShock Pin 8 = Battery + InstallationPin 2 = Keyswitch Pin 5 = BatteryPins 1, 2, 6 & 7 = Hour Meter Control + Pin 4 = Relay Pin 3 = Relay +Model Switch MeterHigh Voltage Maximum MinimumSetting Discharge AdjustmentsCurtis Model 833 Rear View Connections for Typical Model 833 Application Display OperationLCD Hour Meter Push-to-read Problem Possible Causes TroubleshootingMaintenance All specifications are subject to change Without notice Kisco Avenue, Mt. Kisco, NY 10549 Tel 666-2971 FAX 914 Curtis INSTRUMENTS, INC