Curtis Computer 833 Pin 5 = Battery, Pin 2 = Keyswitch, Pins 1, 2, 6 & 7 = Hour Meter Control +

Page 10

Pin 5 = Battery –

Connect to battery ground as close to battery ! as possible.

Pin 2 = Keyswitch

The keyswitch turns on and off the LED display of the battery discharge indicator. Monitoring of the battery continues when Pin 2 is turned off and the display is not lit.

The hour meter display is unaffected by Pin 2, although it cannot accumulate more time as long as the keyswitch pin is not energized. The control input HRM

(+)is enabled by the keyswitch. Pin 2 is connected to the vehicle’s keyswitch.

Pins 1, 2, 6 & 7 = Hour Meter Control (+)

In normal operation, Pin 1, 6 or 7 are connected when using normal hour meter function. It is possible to OR the hour meter between the three inputs so that it accumulates the total time either system is on. Hour meter control logic is detailed in Table 2.

8

Image 10
Contents Model Read Instructions CarefullySafety Instructions Table of Contents Model Encodement 833RB VvvvZzzz Operating Current Technical SpecificationsElectrical Operating Range Relay Contact RatingsHardware Kit ResolutionMechanical Display Panel CutoutEnvironmental TemperatureShock Installation Pin 8 = Battery +Pin 2 = Keyswitch Pin 5 = BatteryPins 1, 2, 6 & 7 = Hour Meter Control + Pin 3 = Relay + Pin 4 = RelayHigh Voltage Switch MeterModel Maximum MinimumDischarge Adjustments SettingCurtis Model 833 Rear View Connections for Typical Model 833 Application Display OperationLCD Hour Meter Push-to-read Troubleshooting Problem Possible CausesMaintenance All specifications are subject to change Without notice Curtis INSTRUMENTS, INC Kisco Avenue, Mt. Kisco, NY 10549 Tel 666-2971 FAX 914