Curtis Computer 833 manual Troubleshooting, Problem Possible Causes

Page 18

5. Troubleshooting

The following checklist should help you to troubleshoot any problems with the instrument.

Problem

Possible Causes

No display

Terminals not connected or

 

improper voltage

Stays at FULL

Instrument voltage does not

 

match battery voltage,

 

B+ connected to the wrong

 

terminal

Will not reset

Instrument voltage does not

 

match battery voltage, or battery

 

not fully charged

Resets w/o charging battery

Not connected directly to

 

battery terminals

EMPTY too soon

B+ connected to wrong terminal,

 

or instrument voltage does not

 

match battery voltage, or

 

terminals not directly connected

 

to battery

16

Image 18 Contents
Model Read Instructions CarefullySafety Instructions Table of Contents Model Encodement 833RB VvvvZzzz Operating Current Technical SpecificationsElectrical Operating Range Relay Contact RatingsHardware Kit ResolutionMechanical Display Panel CutoutTemperature EnvironmentalShock Installation Pin 8 = Battery +Pin 5 = Battery Pin 2 = KeyswitchPins 1, 2, 6 & 7 = Hour Meter Control + Pin 3 = Relay + Pin 4 = RelayHigh Voltage Switch MeterModel Maximum MinimumDischarge Adjustments SettingCurtis Model 833 Rear View Connections for Typical Model 833 Application Operation DisplayLCD Hour Meter Push-to-read Troubleshooting Problem Possible CausesMaintenance All specifications are subject to change Without notice Curtis INSTRUMENTS, INC Kisco Avenue, Mt. Kisco, NY 10549 Tel 666-2971 FAX 914