Omron HCG-801 instruction manual Error Messages, Menu

Page 48

HCG-801-E.book Page 48 Tuesday, December 13, 2011 5:35 PM

10. Care and Maintenance

 

 

Message

 

Cause

Remedy

 

 

 

 

 

 

 

 

 

The unit is unable to access data

Refer to the instruction supplied

 

 

 

with the memory card and insert

 

SD is write-protected.

because the SD memory card

 

the SD memory card with write-

 

 

 

inserted is write-protected.

 

 

 

protection turned off.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Insert new batteries and reset the

 

 

 

The battery power has run low

Date and Time and other

 

No saved data.

and the ECG data stored on the

settings. Any ECG data that was

 

 

 

unit has disappeared.

stored on the unit cannot be

 

 

 

 

 

recovered.

 

 

 

The battery power has run low

Insert new batteries and reset the

 

Set clock.

 

and the Date and Time setting on

Date and Time from the SET

 

 

 

the unit has disappeared.

menu.

 

No saved data.

The battery power has run low

Insert new batteries and reset the

 

and the ECG data stored on the

 

Date and Time and other

 

Set clock.

 

unit has disappeared or the clock

 

 

settings.

 

 

 

has been reset.

 

 

 

 

Error Messages

 

 

 

 

 

 

 

 

 

 

Error #

Message

 

Cause

Remedy

 

 

 

 

 

 

 

01

Please insert new

 

The batteries are worn out.

Replace both batteries with new

 

batteries.

 

ones.

 

 

 

 

 

 

Device memory error

An error occurred while

 

 

11

trying to read ECG data

 

 

Cannot read data.

 

 

 

 

 

stored in unit memory.

 

 

 

 

 

Try again.

 

 

 

 

 

 

 

Device memory error

An error occurred while

 

 

If the error still occurs, consult

 

12

trying to erase ECG data

 

Cannot erase data.

 

your OMRON service

 

 

 

stored in unit memory.

 

 

 

 

representative.

 

 

 

 

 

 

 

Device memory error

An error occurred while

 

 

 

 

13

trying to save ECG data to

 

 

Cannot write data.

 

 

 

 

 

unit memory.

 

 

 

 

 

 

48

Image 48
Contents Model HCG-801 Portable, cordless, single-channel ECG MonitorContents Introduction Intended UseThis unit has no function to detect pacing spikes General Know Your Unit Main UnitReplacements Parts Settings SET menu screen DisplayMenus Menu screenECG Graph Inserting and Replacing Batteries Battery life and replacement Battery lifeHCG-801-E.book Page 12 Tuesday, December 13, 2011 535 PM Setting the Date and Time Unit beeps, then the power is turned off Using SD Memory Card Inserting and Ejecting SD Memory CardInserting the SD memory card Never insert an SD memory card while the unit is turned onWrite Protection Locking the SD Memory Card Close the SD memory card slot cover Only eject an SD memory card when the unit is turned off To eject the SD memory cardFormatting an SD Memory Card Never remove an SD memory card while it is being formatted Important Notes on Taking a Measurement Do not move during measurementTaking a Measurement Press closely to your chest Female About 30 seconds HCG-801-E.book Page 25 Tuesday, December 13, 2011 535 PM Common Causes of Inaccurate Measurement Results Measurement Result There are 13 messages regarding the measurement resultRecommendation on measurement result Displaying ECG Data Displaying ECG Data Adjusting the Settings Basic OperationAdjusting the Settings Volume Date and TimeBrightness Contrast Language Date Format Messages Overwrite About the Overwrite messageManaging ECG Data Erasing ECG Data Erasing All ECG DataMessage Erase all data in SD memory? is displayed Erasing Selected ECG Data HCG-801-E.book Page 41 Tuesday, December 13, 2011 535 PM Copying Data to an SD Memory Card Press the OK button ECG data is copied to the SD memory card Copying data from the SD memory card to a PC Copying data from the SD memory card to a PC Copying data from a PC to the SD memory card Care and Maintenance Lists and Explanations of MessagesMessage Cause Remedy Error Messages MenuSD memory error Trying to erase ECG data Troubleshooting Problem Cause SolutionMaintenance and Storage Technical Data Internally Powered Type BFTechnical Data General Information About the Heart and ECG Measurements What is Arrhythmia? What is Ischemia?About the ECG Waveform Omron Healthcare Europe B.V