Pelco PSKIT8100 Pressure Sensor Installation, EH8100 Series Enclosure Rear Plate, Inside View

Page 7

Pressure Sensor Installation

To install the pressure sensor, perform the following steps.

1.Remove the screw located inside the top portion of the enclosure’s rear plate (refer to Figure 2). Insert the pressure sensor tube fitting in the hole.

2.Loosen the camera sled mounting screws (refer to Figure 2). Slide the sensor bracket under the mounting screws and ground lug. Tighten the screws.

3.Connect the wire leads (refer to Figure 2 and Figure 3):

a.Green/white wire - Insert the push-on lug into the connector on the pressure sensor assembly. Connect the spade lug to the power terminal block under the AC NEUT wire.

b.White/green wire - Insert the push-on lug into the connector on the pressure sensor assembly. Connect the spade lug to the power terminal block above the AC LINE wire.

INSERT TUBE

FITTING

REMOVE

SCREWWHITE/GREEN

WIRE

GROUND STUD

GREEN/WHITE

 

WIRE

CAMERA SLED

SLIDE SENSOR BRACKET

UNDER MOUNTING SCREWS

AND GROUND STUD

Figure 2. EH8100 Series Enclosure - Rear Plate, Inside View

C1445M-D (11/04)

7

Image 7
Contents PSKIT8100 Page List of Illustrations ContentsPage Description Important Safeguards and WarningsEnclosure Disassembly InstallationEH8100 Series Enclosure Rear Plate, Inside View Pressure Sensor InstallationEH8100 Series Enclosure Wiring Diagram Reassembly Enclosure Reassembly and RechargingPage Product Warranty and Return Information ISO9001