Teledyne HFC-E-202, HFM-E-200 instruction manual Manual Print History

Page 2

Manual Print History

The print history shown below lists the printing dates of all revisions and addenda created for this manual. The revision level letter increases alphabetically as the manual undergoes subsequent updates. Addenda, which are released between revisions, contain important change information that the user should incorporate immediately into the manual. Addenda are numbered sequentially. When a new revision is created, all addenda associated with the previous revision of the manual are incorporated into the new revision of the manual. Each new revision includes a revised copy of this print history page.

Revision A (Document Number 138-102002)

October 2002

Revision B (Document Number 138-102004)

October 2004

Revision C (Document Number 138-082005)

August 2005

Revision D (Document Number 138-032007)

March 2007

Revision E (Document Number 138-092008)

September 2008

Revision E (Document Number 138-082010)

August 2010

Visit www.teledyne-hi.com for WEEE disposal guidance.

CAUTION:

CAUTION:

CAUTION:

The instruments described in this manual are available with multiple pin-outs. Ensure that all electrical connections are correct.

The instruments described in this manual are designed for INDOOR use only.

The instruments described in this manual are designed for Class 2 installations in accordance with IAW/IPC standards

Hastings Instruments reserves the right to change or modify the design of its equipment without

any obligation to provide notification of change or intent to change.

HFM-E-200/HFC-E-202

Page 2 of 30

Image 2
Contents Teledyne Hastings Manual Print History Table of Contents Installation and Operation FeaturesSpecifications Swagelok, 1/8 Swagelok, VCR, VCOInterconnecting Cables Other AccessoriesHastings Power supplies Optional 4-20 mA Current OutputReceiving Inspection Power RequirementsOutput Signal Mechanical ConnectionsElectrical Connections Zero Check OperationOperating Conditions Operation with External Devices Operation with a Hastings power supplyOperation with a power supply other than a Hastings High Pressure OperationSoft Start Range ChangingOperation with an external sensor. Fig Sensor Theory of OperationOverall Functional Description ElectronicsShunt Valve Troubleshooting MaintenanceAuthorized Maintenance Adjustments Calibration Procedure FigureMiscellaneous adjustments Printed Circuit Board ReplacementSensor Replacement Inlet Removal0014 Q HFC-E-202 OrificeReplacement Parts Conversion Factor Table BF3C2H7N C3H8O SO2 Warranty Repair Policy Non-Warranty Repair PolicyDrawings HFM-E-200/HFC-E-202 HFM-E-200/HFC-E-202 HFM-E-200/HFC-E-202 HFM-E-200/HFC-E-202 HFM-E-200/HFC-E-202

HFC-E-202, HFM-E-200 specifications

Teledyne HFC-E-202 and HFM-E-200 are advanced flow meters designed to provide precise measurement and monitoring of gas and liquid flows in various industrial applications. Both devices are engineered to meet the demands of sectors such as petrochemicals, pharmaceuticals, and food and beverage, where accuracy and reliability are paramount.

The Teledyne HFC-E-202 is a highly sensitive flow meter that utilizes a thermal mass flow measurement technology. This technology enables the HFC-E-202 to accurately measure the mass flow rate of gases regardless of temperature and pressure conditions. One of its key features is its ability to provide high precision and fast response times, making it suitable for applications that require immediate data feedback. The device is also equipped with advanced diagnostics that allow users to monitor the health of the system and identify potential issues before they escalate.

On the other hand, the HFM-E-200 is particularly renowned for its versatility in measuring both gas and liquid flows. It employs differential pressure technology, which is highly effective in a wide range of operating conditions. The HFM-E-200 incorporates a robust design that can withstand harsh environments, ensuring longevity and reliability. Its user-friendly interface allows for easy configuration and monitoring, catering to both novice and experienced technicians.

Both flow meters feature digital output options, facilitating seamless integration with existing control systems. This enables real-time data acquisition and monitoring, enhancing process control and efficiency. Furthermore, their compact design minimizes installation space, allowing for easy placement in tight operational areas.

In terms of safety and compliance, both the HFC-E-202 and HFM-E-200 are designed to meet strict industry standards, ensuring they can be deployed in critical applications without compromising safety.

In conclusion, Teledyne HFC-E-202 and HFM-E-200 flow meters stand out due to their innovative technologies, accuracy, and durability. Their unique features position them as essential tools for a variety of industrial sectors, enhancing operational efficiency and ensuring reliable fluid flow measurement. With Teledyne’s commitment to quality and innovation, users can trust that these devices will meet their demands both now and in the future.