Teledyne HFM-E-200, HFC-E-202 instruction manual Specifications, Swagelok, 1/8 Swagelok, VCR, VCO

Page 5

1.2. Specifications

Accuracy

±1% full scale (F.S.)

Repeatability

<±0.125% of F.S.or ±0.075% of rdg. +0.05% F.S. (max)

Maximum operational pressure

500 psi [3.45 MPa]

...................................................................................................

(Option-P- up to 1000 psi [6.9 MPa]

Pressure coefficient

<0.0067% of reading/psi (N2)

...............................................................................................

See pressure section for pressure errors.

Normal operating temperature

10-50°C in non-condensing environment

Operating temperature limits

0-60°C non-condensing

Temperature coefficient (zero)

maximum ±0.085%/°C (from 10 to 50oC)

Temperature coefficient (span)

maximum ±0.05%/°C (from 10 to 50oC)

Leak integrity

<1x10-9 std. cc/s.

Standard flow ranges

5, 10, 20, 50, 100, 200, 500, sccm.

.............................................................................................

1, 2, 5, 10, 20, 30* slpm (N2 equivalent)

Standard output

0-5 VDC (load 2k Ohms)

Optional output

4 -20 mA (load < 600 Ohms when loop return is @ common)

........................................................................

(600-1200 Ohm load when loop return is @ -15VDC)

Power requirements

+(14 to 16) VDC @ 45 mA, -(14 to 16) VDC @ 185 mA

Wetted materials

302 & 316 stainless steel, nickel 200,

........................................................

Viton (optional), 82/18 Au-Ni braze, Kalrez, silver solder (trace)

Attitude sensitivity of zero

< ±0.25% F.S. for 90° without re-zeroing

................................................................................................................

{N2 at 44.7 psia (308 KPa)}

Controller weight

1.6 lb (0.6 kg) approx.

Meter weight

1.6 lb (0.6 kg) approx.

Electrical connector

15 pin subminiature “D”

Standard fittings

1/4” Swagelok®, 1/8” Swagelok®, VCR®, VCO®

* (Specifications may vary for instruments with ranges greater than 10 slpm)

HFM-E-200/HFC-E-202

Page 5 of 30

Image 5
Contents Teledyne Hastings Manual Print History Table of Contents Features Installation and OperationSwagelok, 1/8 Swagelok, VCR, VCO SpecificationsHastings Power supplies Other AccessoriesInterconnecting Cables Optional 4-20 mA Current OutputOutput Signal Power RequirementsReceiving Inspection Mechanical ConnectionsElectrical Connections Zero Check OperationOperating Conditions Operation with a power supply other than a Hastings Operation with a Hastings power supplyOperation with External Devices High Pressure OperationSoft Start Range ChangingOperation with an external sensor. Fig Overall Functional Description Theory of OperationSensor ElectronicsShunt Valve Troubleshooting MaintenanceAuthorized Maintenance Calibration Procedure Figure AdjustmentsSensor Replacement Printed Circuit Board ReplacementMiscellaneous adjustments Inlet RemovalHFC-E-202 Orifice 0014 QReplacement Parts BF3 Conversion Factor TableC2H7N C3H8O SO2 Non-Warranty Repair Policy Warranty Repair PolicyDrawings HFM-E-200/HFC-E-202 HFM-E-200/HFC-E-202 HFM-E-200/HFC-E-202 HFM-E-200/HFC-E-202 HFM-E-200/HFC-E-202

HFC-E-202, HFM-E-200 specifications

Teledyne HFC-E-202 and HFM-E-200 are advanced flow meters designed to provide precise measurement and monitoring of gas and liquid flows in various industrial applications. Both devices are engineered to meet the demands of sectors such as petrochemicals, pharmaceuticals, and food and beverage, where accuracy and reliability are paramount.

The Teledyne HFC-E-202 is a highly sensitive flow meter that utilizes a thermal mass flow measurement technology. This technology enables the HFC-E-202 to accurately measure the mass flow rate of gases regardless of temperature and pressure conditions. One of its key features is its ability to provide high precision and fast response times, making it suitable for applications that require immediate data feedback. The device is also equipped with advanced diagnostics that allow users to monitor the health of the system and identify potential issues before they escalate.

On the other hand, the HFM-E-200 is particularly renowned for its versatility in measuring both gas and liquid flows. It employs differential pressure technology, which is highly effective in a wide range of operating conditions. The HFM-E-200 incorporates a robust design that can withstand harsh environments, ensuring longevity and reliability. Its user-friendly interface allows for easy configuration and monitoring, catering to both novice and experienced technicians.

Both flow meters feature digital output options, facilitating seamless integration with existing control systems. This enables real-time data acquisition and monitoring, enhancing process control and efficiency. Furthermore, their compact design minimizes installation space, allowing for easy placement in tight operational areas.

In terms of safety and compliance, both the HFC-E-202 and HFM-E-200 are designed to meet strict industry standards, ensuring they can be deployed in critical applications without compromising safety.

In conclusion, Teledyne HFC-E-202 and HFM-E-200 flow meters stand out due to their innovative technologies, accuracy, and durability. Their unique features position them as essential tools for a variety of industrial sectors, enhancing operational efficiency and ensuring reliable fluid flow measurement. With Teledyne’s commitment to quality and innovation, users can trust that these devices will meet their demands both now and in the future.