Teledyne HFC-E-202, HFM-E-200 instruction manual Installation and Operation, Features

Page 4

1. Installation and Operation

The Hastings HFM-E-200 mass Flow-meter and HFC-E-202 Flow-controller are designed to accurately measure and control mass flow over the range of 10 sccm to 30 slm, without corrections or compensations for gas pressure and temperature with an accuracy of better than ±1% FS. Hastings mass flow instruments do not require any periodic maintenance under normal operating conditions with clean gases. No damage will occur from the use of moderate overpressures (~500 psi/3.45MPa) or overflows. Instruments are normally calibrated with the appropriate standard calibration gas (nitrogen) then a correction factor is used to adjust the output for the intended gas

1.1.Features

LINEAR BY DESIGN. The HFM-E-200/HFC-E-202 series is inherently linear (no linearization circuitry is employed). Should recalibration in the field be desired (a calibration standard is required), the customer needs to simply set the zero and span points. There will be no appreciable linearity change of the instrument when the flowing gas is changed.

MODULAR SENSOR. The HFM-E-200/HFC-E-202 series incorporates a removable/replaceable sensor module. Field repairs to units can be achieved with a minimum of production line downtime.

LOW TEMPERATURE DRIFT. The temperature coefficient of span for the HFM-E-200/HFC-E-202 series is typically less than 0.05% of full scale/°C from 10-50°C. The temperature coefficient of zero is typically less than 0.1 % of reading/°C from 10-50°C.

CURRENT LOOP. The 4-20 mA option gives the user the advantages of a current loop

output to

minimize environmental noise pickup.

 

HFM-E-200/HFC-E-202

Page 4 of 30

Image 4
Contents Teledyne Hastings Manual Print History Table of Contents Installation and Operation FeaturesSpecifications Swagelok, 1/8 Swagelok, VCR, VCOOther Accessories Hastings Power suppliesInterconnecting Cables Optional 4-20 mA Current OutputPower Requirements Output SignalReceiving Inspection Mechanical ConnectionsElectrical Connections Operating Conditions OperationZero Check Operation with a Hastings power supply Operation with a power supply other than a HastingsOperation with External Devices High Pressure OperationOperation with an external sensor. Fig Range ChangingSoft Start Theory of Operation Overall Functional DescriptionSensor ElectronicsShunt Valve Authorized Maintenance MaintenanceTroubleshooting Adjustments Calibration Procedure FigurePrinted Circuit Board Replacement Sensor ReplacementMiscellaneous adjustments Inlet Removal0014 Q HFC-E-202 OrificeReplacement Parts Conversion Factor Table BF3C2H7N C3H8O SO2 Warranty Repair Policy Non-Warranty Repair PolicyDrawings HFM-E-200/HFC-E-202 HFM-E-200/HFC-E-202 HFM-E-200/HFC-E-202 HFM-E-200/HFC-E-202 HFM-E-200/HFC-E-202

HFC-E-202, HFM-E-200 specifications

Teledyne HFC-E-202 and HFM-E-200 are advanced flow meters designed to provide precise measurement and monitoring of gas and liquid flows in various industrial applications. Both devices are engineered to meet the demands of sectors such as petrochemicals, pharmaceuticals, and food and beverage, where accuracy and reliability are paramount.

The Teledyne HFC-E-202 is a highly sensitive flow meter that utilizes a thermal mass flow measurement technology. This technology enables the HFC-E-202 to accurately measure the mass flow rate of gases regardless of temperature and pressure conditions. One of its key features is its ability to provide high precision and fast response times, making it suitable for applications that require immediate data feedback. The device is also equipped with advanced diagnostics that allow users to monitor the health of the system and identify potential issues before they escalate.

On the other hand, the HFM-E-200 is particularly renowned for its versatility in measuring both gas and liquid flows. It employs differential pressure technology, which is highly effective in a wide range of operating conditions. The HFM-E-200 incorporates a robust design that can withstand harsh environments, ensuring longevity and reliability. Its user-friendly interface allows for easy configuration and monitoring, catering to both novice and experienced technicians.

Both flow meters feature digital output options, facilitating seamless integration with existing control systems. This enables real-time data acquisition and monitoring, enhancing process control and efficiency. Furthermore, their compact design minimizes installation space, allowing for easy placement in tight operational areas.

In terms of safety and compliance, both the HFC-E-202 and HFM-E-200 are designed to meet strict industry standards, ensuring they can be deployed in critical applications without compromising safety.

In conclusion, Teledyne HFC-E-202 and HFM-E-200 flow meters stand out due to their innovative technologies, accuracy, and durability. Their unique features position them as essential tools for a variety of industrial sectors, enhancing operational efficiency and ensuring reliable fluid flow measurement. With Teledyne’s commitment to quality and innovation, users can trust that these devices will meet their demands both now and in the future.